Installation Manual

Table Of Contents
Commissioning Procedures
4-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.
CONFIDENTIAL & PROPRIETARY
D
O
N
O
T
C
O
P
Y
5 Set the 48 Vdc power source to ON.
6 Remove the protective cap from the IFU test connector.
7 Connect the IFU test cable to the test port of the near-end IFU.
Figure 4-2. Alignment Test Setup
8 Connect the BNC plug of the test cable to the BNC/banana interface
cable.
9 Connect the banana plug of the BNC/banana interface cable to the
multimeter (red plug to the volt terminal, black plug to the Common
terminal).
DANGER HIGH CURRENT HAZARD: Do not turn
on power before reading the Triton Network Systems
product documentation. This device has a 48 Vdc
(4 amps operating peak per feed) direct current input.
DANGER LHASARD DU COURANT ÉLEVÉ : Ne
pas mettre la tension avant de lire la documentation du
produit fournie par la société Triton Network Systems. Cet
appareil a une alimentation directe de 48 V CC (courant
de pointe de 4 ampères par ligne dalimentation).
IFU
LAPTOP WITH
IFU LINK MANAGER
TEX T
TEX T
TEX T TEX T
TEX T TEX T
T E XT TE XT
T E XT TE XT
TEX T
TE XT
3
+
-
TEST CABLE
BNC/BANANA
MULTIMETER