Installation Manual

Table Of Contents
Staging Procedure
2-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.
2 Connect the IFU power cable to the – 48 Vdc power source as shown in
Figure 2-2.
Figure 2-2. IFU Power Cable Hookup
3 Set the – 48 Vdc power source to ON.
4 Set the multimeter to DC voltage.
5 Connect a black test lead from the negative input of the multimeter to
pin B on the IFU power cable (see Figure 2-3).
Figure 2-3. Power Test Setup
Power
Cable
- 48 Vdc Power
Source
- 48
RTN
RTN White (Cable Pin A)
RTN White/Red (Cable Pin B)
- 48 White/Brown (Cable Pin C)
- 48 White/Black (Cable Pin D)
Cable Pin Assignment