Alignment Procedures
4-4 © 1999 Triton Network Systems, Inc. All Rights Reserved.
3 Loosen the horizontal alignment nut on the holding bracket. Coarse align
the near-end IFU to the designated far-end IFU using an optical alignment
tool.
4 Tighten the four vertical screws and single horizontal nut on the IFU
mounting bracket.
5 Set the – 48 Vdc power source to ON.
6 Remove the protective cap from the IFU test connector.
7 Connect the IFU test cable to the test port of the near-end IFU (see
Figure 4-2).
Figure 4-2. Alignment Test Setup
DANGER – HIGH CURRENT HAZARD: Do not turn
on power before reading the Triton Network Systems’
product documentation. This device has a – 48 Vdc
(5 amps operating peak per feed) direct current input.
DANGER – L’HASARD DU COURANT ÉLEVÉ : Ne
pas mettre la tension avant de lire la documentation du
produit fournie par la société Triton Network Systems. Cet
appareil a une alimentation directe de – 48 V CC (courant
de pointe de 5 ampères par ligne d’alimentation).
Laptop with
IFU Link Manager
TEXT
TEXT
TEXT TEXT
TEXT TEXT
TEXT TEXT
TEXT TEXT
TEXT
TEXT
3
+
-
Test Cable
BNC/Banana
Multimeter
IFU