MODEL FT5000XP PC-BASED ATM INSTALLATION GUIDE VERSION 1.0 TDN 07102-00059 Mar 24 2009 CORPORATE HEADQUARTERS: RMA (RETURN MATERIAL AUTHORIZATION) RETURN ADDRESS: 522 E. Railroad Street Long Beach, MS 39560 PHONE: (228) 868-1317 FAX: (228) 868-0437 21405 Avenue “B” Long Beach, MS 39560 COPYRIGHT NOTICE © 2008 Delaware Capital Formation, Inc. All Rights Reserved. TRITON, TRITON WHERE MONEY COMES FROM, TRITON WAVES, DOVER and DOVER logo are registered trademarks of Delaware Capital Formation, Inc.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE WHAT’S IN THIS INSTALLATION GUIDE This Installation Guide provides information for the preparation and installation of the FT5000XP ATM. It contains requirements for site preparation, electrical specifications, and cabinet accessibility that comply with all relevant codes, laws and regulations. The Installation Guide is divided into the following sections: COMPLIANCE NOTIFICATIONS. ATM INSTALLATION FOR ACCESSIBILITY.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE INTRODUCTION This document contains the information necessary for the preparation and installation of an FT5000XP Triton ATM. It’s important that the site complies with the requirements specified in this document. In addition, electrical wiring and mechanical systems must also comply with all relevant laws and regulations.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE DISCLAIMER The manufacturer of theAutomated Teller Machine (ATM) product(s) described herein makes no representations or warranties, either expressed or implied, by or with respect to anything in this manual, and shall not be liable for any implied warranties of fitness for a particular purpose or for any indirect, special, or consequential damages.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE Harm to the Network: If the FT5000XP ATM causes harm to the telephone network, the telephone company will notify the customer that a temporary discontinuous of service may be required. If advanced notice is not possible, the telephone company will notify the customer as soon as possible.You will be advised of your right to file a complaint with the FCC if you believe it’s necessary.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE UNITED KINGDOM This equipment has been approved in accordance with Council Decision 98/482/EC for pan-European single terminal connection to the Public Switched Telephone Network (PSTN). However, due to differences between the individual PSTNs provided in the different countries, the approval does not, of itself, give unconditional assurance of successful operation on every PSTN network termination point.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE THIS PAGE INTENTIONALLY LEFT BLANK 8
ATM INSTALLATION FOR ACCESSIBILITY 9
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE ATM INSTALLATION FOR ACCESSIBILITY 4.34 1. This document supersedes all other information provided by Triton for ATM installation for accessibility. 2. Information provided in this manual is based on federal guidelines (ADAAccessibility Guidelines for Buildings and Facilities – ADAAG) as amended through January 1998. You should verify it has not been amended. States may also have accessibility codes.
ATM INSTALLATION FOR ACCESSIBILITY (b) Reach Depth MoreThan 10 inches (255 mm).
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE 4.2.4 Clear Floor or Ground Space for Wheelchairs. 4.2.4.1 Size and Approach. Theminimum clear floor or ground space required to accommodate a single, stationary wheelchair and occupant is 30 inches by 48 inches (760 mm by 1220 mm) (see Fig. 4a). The minimum clear floor or ground space for wheelchairs may be positioned for forward or parallel approach to an object (see Fig. 4b and 4c).
ATM INSTALLATION FOR ACCESSIBILITY 4.2.6 Side Reach. If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 inches (1370 mm) and the low side reach shall be no less than 9 inches (230 mm) above the floor (Fig. 6(a) and 6(b)). If the side reach is over an obstruction, the reach and clearances shall be as shown in Fig 6(c). Figures 4d . Clear Floor Space in Alcoves. Figures 4e. Clear Floor Space in Alcove.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE Figure 5a. Forward reach, unobstructed. Figure 5b. Forward reach, obstructed. Figure 6a. Parallel approach - side reach. Figure 6b. Parallel approach - high/ low side reach.
ATM INSTALLATION FOR ACCESSIBILITY Figure 6c. Side reach, ob structed. Outside H andicap Access Area 48" (1219 mm) - Across - 30" (762 mm) - D eep - * Measured from center of C ontrol P anel Fascia * Floor Interior Ground exterior Figure 7. ADA access dimensions for FT5000XP ATM.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE THIS PAGE INTENTIONALLY LEFT BLANK 16
ENVIRONMENTAL PRECAUTION CHECKLIST 17
ATM ENVIRONMENTAL PRECAUTIONS CHECKLIST When installing anATM, some general environmental and power precautions need to be considered. Evaluate the location where the ATM will be installed. To help ensure proper operation of theATM, ensure the environmental criteria listed in this checklistare met. Dedicated sour ce. The ATMs AC power feed will be a dedicated line to which no other electrical devices are connected.
SITE PREPARATION / INSTALLATION 19
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE INTRODUCTION The Triton FT5000 is a self-serviced, weatherized terminal adaptable for any suitable exterior wall or vestibule location. The cabinet design allows flexibility for “Island” installations (wall thickness up to 6-1/4") or existing structures (wall thickness up to 10"). Built-in leveling feet and optional platforms (“plinths”) allow the unit to be raised to the desired height of the wall opening.
SITE PREPARATION/INSTALLATION EXTERIOR WALL DIMENSIONS The following illustrations show the nominal wall area dimensions required for installation. Wall opening dimensions have a plus/minus (+/-) 1/4" tolerance.The height of the opening is from exterior sidewalk level to the base of the opening to comply with FederalADA requirements.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE HEIGHTS TO MAIN CONTROL PANEL The following illustrations show the heights and the FederalADA requirements to the main control panel items located on the FT5000XP. All the height dimensions are calculated from the base of theexterior ground level to each item. Heights to Main Control Panel Items Top Ht.
SITE PREPARATION/INSTALLATION DETERMINE IF UNIT NEEDS A PLINTH Triton Systems offers two (2) metal-constructed optional “plinths” w/leveling feet. A plinth is a platform on which theATM rests or is secured and enables the ATM to be installed at the required height through the wall.The plinths come in 2 heights: 2-3/8” (61mm) and 4-3/4” (122 mm).You can raise the unit by a fixed amount (2-3/8"or 4-3/4") and still be able to adjust up using theplinths leveling feet.
6 -1/4" max 6 -1/4" max 6 -1/4" max * Dimensions shown in inches and millimeters.
SITE PREPARATION/INSTALLATION EXTENDED CONFIGURATION SERVICE AREA 10" max 10" max * Dimensions shown in inches and millimeters.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE SECURING UNIT It’s recommended that the unit be secured to the facility floor and plinth structure. If a plinth was used, we recommend anchoring that structure first due to accessibility may be limited once the unit is mounted on the plinth. The footprint of the cabinet floor allows for securing to either a concrete pad or plinth structure.
SITE PREPARATION/INSTALLATION INSTALLING CABINET THROUGH WALL OPENING 1. Carefully inspect the unit for any shipping damage and report any damage immediately to the shipping company. Refer to the warranty information in the user or service manual (as applicable) for information about reporting shipping damage. 2. After unpacking the unit, remove the dispensing mechanism following the procedures in the section “NMD-100 Dispensing Mechanism:Removal/ Installation” found on pages 4447.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE 5. If no plinth is needed, slide the unit forward towards the wall opening so the sleeve protrudes slightly out the front exterior (Figure 4). This is needed to temporarily affix the control panel trim. Minor adjustments for raising the unit can be made using thecabinet leveling feet (See “Adjusting Height of Unit” page 30). 6. If a plinth is used (either built or purchased), mount the cabinet on the plinth Figure 5).
SITE PREPARATION/INSTALLATION Figure 6a. Location of clips on control panel trim. 9. Figure 6b. Location of slots on sleeve control panel. Temporarily mount the trim on the protruding sleeve. DO NOT secure with screws at this time. 10. Slide the unit back until the control panel trim is flush to the exterior wall (Figure 7). 11. Adjust the plinth’s leveling feet to ensure the control panel trim is flush against the exterior wall and the cabinet is level. 12.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE Adjusting Height of Unit Triton Systems offers two (2) metal-constructed optional plinths w/leveling feet. The plinths come in 2 heights: 2 - 3/8" (61 mm) and 4 - 3/4" (122 mm). Based on the height requirement needed, you can either: 1) Raise the unit with the leveling feet installed in the cabinet (Business Hours and Level 1) using a 1/4" (6mm) nut driver/socket.
SITE PREPARATION/INSTALLATION INSTALLING CONTROL PANEL TRIM 1. Locate the control panel trim included with the unit accessories. On the back side are 4 clips (Figure 1a) that will align with 4 slots on the sleeve control panel (Figure 1b). 2. Before mounting the trim, ensure the speaker wires and LED light cables are routed through the opening above the control panel. These will be connected later. Align the trim clips with the sleeve slots and insert until the trim is seated on the control panel. 3.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE 4. After the control panel trim has been secured, route the speaker wires through the cable clip shown in Figure 3. Connect the speaker wires to the audio input circuit board located in the lower right corner of the cabinet (Figure 4). 5. Connect the trims upper LED light cable to the cabinets LED light assembly shown in Figure 5. Connect the lower cable to the docking board assembly (J3) shown in Figure 6. 6.
SITE PREPARATION/INSTALLATION EXTENDED CONFIGURATION The illustration on right shows the FT5000XP extended. The primary purpose for this configuration is for installation in facilities with exterior walls having a maximum thickness of 10 inches (254 mm). The dispensing mechanism has a bill chute extension designed for the elongated configuration. A protective plate is inserted on the underside of the cabinet sleeve for security and environmental purpose.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE SEALING THE CONTROL PANEL TRIM To ensure that the temperature around the unit is maintained during cold weather, it’s important that the wall opening is prepared correctly . Any cavity in the wall should be sealed to provide a flush surface. The gap between the ATM and the inside wall opening should be left clear to allow air to circulate at room temperature.
SITE PREPARATION/INSTALLATION CABINET DIMENSIONS The following illustrations show dimensions of the cabinet in the Extended and Island configurations. Note: Plinths shown are with the 4-3/4" option. * These dimensions are only accurate if inside and outside “floor” level is the same. If not, the dimensions should be modified accordingly.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE CABINET DIMENSIONS Top View (Island) Wall (6-1/4” max) Top View (Extended) Wall (10” max) 36
SITE PREPARATION/INSTALLATION CABINET DIMENSIONS 6-1/4" WALL Side View (Island) Cable entry * 4-3/4" Plinth Floor-interior Groundexterior 10" WALL Side View (Extended) * 4-3/4" Plinth Floor-interior 37 Cable entry Groundexterior
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE THIS PAGE INTENTIONALLY LEFT BLANK 38
POWER AND COMMUNICATION 39
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE CONNECTING AC POWER AND ETHERNET CABLE 1. Unlock and open the control panel sleeve door. Rotate the Rear Service Display and Keyboard Assembly out by pulling down the locking pin. Verify that the power switch located on the power supply (Figure 1) is in the OFF (0) position. Close the control panel door. 2. Open the security vault door . Ensure the power and Ethernet cables are routed through the cable clips located in the vault cabinet (Figure 2). 3.
POWER AND COMMUNICATION *** WARNING*** This unit may be equipped with more than one power cord. DISCONNECT ALL POWER CORDS PRIOR TO SERVICING! POWER SUPPLY CORD SPECIFICATIONS POWER OUTLET ACCESSIBILITY Whether you are installing a new outlet, or plan to use an existing outlet to supply power to the ATM, make sure the following requirements are met: 1. For European applications, the power supply cord must conform to the following specifications: The outlet is located near the cabinet. 2.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE THIS PAGE INTENTIONALLY BLANK 42
NMD-100 DISPENSING MECHANISM REMOVAL / INSTALLATION 43
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE REMOVING/INSTALLING THE NMD-100 DISPENSING MECHANISM The dispensing mechanism for the FT5000XP unit is shipped mounted on the slide rails inside the security vault. Several protective foam packs have been strategically placed behind and along each side of the dispensing mechanism to reduce any movement during transit. The foam packs and cardboard that secures the cassettes must be removed before the dispensing mechanism can be extended out.
NMD-100 DISPENSING MECHANISM REMOVAL/INSTALLATION 5. Turn the dispenser power switch located just to the right of the power connector to OFF (0) (Figure 4). 6. Refer to Figures 4 and 5. Disconnect the DC power , serial communications, and shutter cables from the dispensing mechanism. Remove the cables from the cable clips attached to sides of dispenser. On/Off switch Shutter cable AC power cable Serial cable Figure 4. Remove AC power cable. Figure 5.
FT5000XP - SITE PREPARATION AND INSTALLATION GUIDE INSTALLING THE DISPENSING MECHANISM INTO THE CABINET Rail slots **CAUTION** Be certain that you have not applied power to the ATM before you continue! See Pg.44 for theATMs power supply location and On/Off switch. 1. 2. Refer to Figure 1. Pull the slide rails out of the cabinet until they reach their fully extended position. The left slide rail has a locking pin that must be disengaged to extend the rail.
NMD-100 DISPENSING MECHANISM REMOVAL/INSTALLATION 4. Refer to Figure 4. Connect the serial communication data cable and the shutter cable to the connectors on the left side of the dispenser . For the serial data cable, use the forward -most connector as shown. The plug is keyed to ensure proper installation. 5. Connect the AC power cable to the dispenser power supply (Figure 5). 6. Disengage the slide rails by lifting up/down on the locking lever located in Figure 6 (both sides).