Installation Manual User guide

FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
305.7 Maneuvering Clearance. Where a clear floor or ground space is located
in an alcove or otherwise confined on all or part of three sides, additional
maneuvering clearance shall be provided in accordance with 305.7.1 and
305.7.2.
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm)wide mini
mum where the depth exceeds 24 inches (610 mm).
Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach
305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide mini-
mum where the depth exceeds 15 inches (380 mm).
Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach
308 Reach Ranges
308.1 General. Reach ranges shall comply with 308.
308.2 Forward Reach.
308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward
reach shall be 48 inches (1220 mm) maximum and the low forward reach
shall be 15 inches (380 mm) minimum above the finish floor or ground.
12