Installation Manual User guide

52
FT5000 - SITE PREPARATION AND INSTALLATION GUIDE
3. Refer to Figure 3. Connect the se-
rial communication data cable and
the shutter cable to the connectors
on the left side of the dispenser.
For the serial data cable, BE SURE
to use the forward -most connec-
tor as shown. The plug is keyed to
ensure proper installation.
2. Pick up the dispensing mechanism
by the handles and load it on to the
slide rail by aligning the tabs (un-
der handle) into the rail slots. (Fig-
ures 1 and 2)
INSTALLING THE DISPENSING MECHA-
NISM INTO THE CABINET
1. Refer to Figure 1. Pull the slide rails
out of the cabinet until they reach
their fully extended position. The
left slide rail has a locking pin that
must be disengaged to extend the
rail. Ensure all cables have been
moved out of the way so they will
not be damaged while installing the
dispensing mechanism in the cabi-
net.
Rail slots
Figure 2. Tab into rail slot. Use 2-
person lift!
Tab
Rail slot
**CAUTION**
Be certain that you have not applied
power to the ATM before you con-
tinue!
Figure 1. Slide rails extended.
**WARNING**
Use only the green handles and drive
motor in rear of dispenser to lift the
mechanism. Two persons recom-
mended to install the dispenser on to
the slide rails.
Figure 3. Shutter and serial data
cable connectors.
Serial communications cable
(Forward-most connector)
Shutter cable