E.6.3 Threshold
The Threshold slide bar allows you to adjust the level of contrast stretching.
When the box is positioned at the left side of the bar, no thresholding is
applied. Maximum thresholding is applied when the box is at the right side of
the bar. If you put a check mark in the
Reverse Colors box, the colors
reverse. The Threshold window can also be summoned by right-clicking on
the contact in Target.
E.6.4 Pan Left, Right, Up or Down
When a contact image is displayed at an expanded scale (any scale other
than 1x), the window remains the same size and only a portion of the image
is visible at any one time. Use the Pan commands to move the window over
the expanded image. The arrow keys provide keyboard shortcuts for the
four pan keys.
When a measurement is made in an expanded image, the display window is
automatically centered on that measurement.
E.7 Format of TGT and CON Files
The TGT and CON types of files of the Target utility are identical in format and
are composed of four types of records, or structures:
a structure that gives the Target utility 16-bit and 32-bit compatibility
a header structure (
cinfo)
an image structure, and
a telemetry structure (
telemetry)
That format is shown in Table E-7. Varieties of data types are used to represent
the structural elements according to the purpose of the elements. The
programming conventions used to represent the various data types are the same
as those used for the XTF format (Appendix D).
Appendix E: Using the Target Utility