Trojan 24TMX Specifications

DATA SHEET 24TMX
CHARGING INSTRUCTIONS
Charger Voltage Settings (at 77°F/25°C)
System Voltage 12V 24V 36V 48V
Bulk Charge 14.82 29.64 44.46 59.28
Float Charge 13.50 27.00 40.50 54.00
Equalize Charge 16.20 32.40 48.60 64.80
Do not install or charge batteries in a sealed or non-ventilated compartment. Constant under or overcharging will damage the battery and shorten its life as with any battery.
STATE OF CHARGE MEASURE OF OPEN-CIRCUIT VOLTAGE
Percentage Charge Specific Gravity Cell 12 Volt
100 1.277 2.122 12.73
90 1.258 2.103 12.62
80 1.238 2.083 12.50
70 1.217 2.062 12.37
60 1.195 2.040 12.24
50 1.172 2.017 12.10
40 1.148 1.993 11.96
30 1.124 1.969 11.81
20 1.098 1.943 11.66
10 1.073 1.918 11.51
OPERATIONAL DATA
Operating Temperature Self Discharge
-4°F to 113°F (-20°C to +45°C). At
temperatures below 32°F (0°C) maintain a
state of charge greater than 60%.
5 – 15% per month depending on storage
temperature conditions.
CHARGING TEMPERATURE COMPENSATION
Add Subtract
0.005 volt per cell for every 1°C below 25°C
0.0028 volt per cell for every 1°F below 77°F
0.005 volt per cell for every 1°C above 25°C
0.0028 volt per cell for every 1°F above 77°F
Designed in compliance with applicable BCI, DIN, BS and IEC standards.
Tested in compliance to BCI and IEC standards.
ELECTRICAL SPECIFICATIONS
Cranking Performance Capacity
A
Minutes Capacity
B
Amp-Hours (AH) Energy (kWh) Internal Resistance (mΩ) Short Circuit Current (amps)
C.C.A.
D
@ 0°F (-18°C) C.A.
E
@ 32°F (0°C)
@ 25 Amps @ 75 Amps 5-Hr 10-Hr 20-Hr 100-Hr 100-Hr
140 36 70 78 85 94 1.13
MODEL 24TMX with POD vent
VOLTAGE 12
MATERIAL Polypropylene
DIMENSIONS Inches (mm)
BATTERY Deep-Cycle Flooded/Wet Lead-Acid Battery
COLOR Maroon
WATERING N/A
PRODUCT + PHYSICAL SPECIFICATIONS
BCI Group Size Type Voltage Cell(s) Terminal Type
G
Dimensions
C
Inches (mm) Weight Lbs. (kg)
Length Width
Height
F
24 24TMX 12 6 7, 8, 9, 16
10.92 (277) 6.62 (168) 9.25 (235)
47 (21)

Summary of content (2 pages)