Trojan SCS200 Specifications

TRJN_SCS200_DS_0315
MODEL: SCS200 with Pod Vent
VOLTAGE: 12
DIMENSIONS: Inches (mm)
BATTERY: Flooded/wet lead-acid battery
COLOR: Maroon (case/cover)
MATERIAL: Polypropylene
WATERING SYSTEM: N/A
PRODUCT SPECIFICATIONS
Page 1 of 2
CHARGING TEMPERATURE COMPENSATION
.028 VPC for every 10°F (5.55°C) above or below 77°F (25°C) (add .028 VPC for every
10°F (5.55°C) below 77°F and subtract .028 VPC for every 10°C above 77°F).
SCS200 DATA SHEET
OPERATIONAL DATA
Operating Temperature Self Discharge
-4°F to 113°F (-20°C to +45°C). At temperatures
below 32°F (0°C) maintain a state of charge
greater than 60%.
5 – 15% per month depending on
storage temperature conditions.
BCI
GROUP
SIZE
TYPE
CAPACITY
A
Minutes
CRANKING
Performance
CAPACITY
B
Amp-Hours (AH)
ENERGY
(kWh)
TERMINAL
Type
G
DIMENSIONS
C
Inches (mm)
WEIGHT
lbs. (kg)
@25
Amps
@75
Amps
C.C.A.
D
@0°F
C.A.
E
@32°F
5-Hr
Rate
10-Hr
Rate
20-Hr
Rate
100-Hr
Rate
100-Hr
Rate
Length Width
Height
F
12 VOLT MARINE/RV DEEP-CYCLE BATTERIES - with T2 TECHNOLOGY
27 SCS200 200 52 620 760 95 105 115 128 1.54 10 12.80 (324) 6.73 (173) 9.80 (248) 60 (27)
A. The number of minutes a battery can deliver when discharged at a constant rate at 80°F (27°C) and maintain a voltage above 1.75 V/cell. Capacities are based on peak performance.
B. The amount of amp-hours (AH) a battery can deliver when discharged at a constant rate at 80°F (27°C) and 86°F (30°C) for the 5-Hour rate and maintain a voltage above 1.75 V/cell. Capacities are based on
peak performance.
C. Dimensions are based on nominal size. Dimensions may vary depending on type of handle or terminal.
D. C.C.A. (Cold Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 0°F at a voltage above 1.2 V/cell.
E. C.A. (Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32°F at a voltage above 1.2 V/cell. This is sometimes referred to as marine cranking
amps @ 32°F or M. C. A. @ 32°F.
F. Dimensions taken from bottom of the battery to the highest point on the battery. Heights may vary depending on type of terminal.
G. Terminal images are representative only.
Trojan’s battery testing procedures adhere to both BCI and IEC test standards.
CHARGING INSTRUCTIONS
CHARGER VOLTAGE SETTINGS (AT 77°F/25°C)
System Voltage 12V 24V 36V 48V
Daily Charge 14.8 29.6 44.4 59.2
Float 13.2 26.4 39.6 52.8
Equalize 15.5 31.0 46.5 62.0
Do not install or charge batteries in a sealed or non-ventilated compartment. Constant
under or overcharging will damage the battery and shorten its life as with any battery.
TM
TERMINAL CONFIGURATIONS
10 DWNT Dual Wingnut Terminal
Terminal Height Inches (mm)
1.57 (39)
Torque Values in-lb (Nm)
95–105 (11 – 12)
Bolt Size
5/16"