Specifications
RECYCLE RESPONSIBLY
12V
AGM
PHYSICAL SPECIFICATIONS
BCI MODEL NAME TERMINAL TYPE
G
DIMENSIONS
C
INCHES (mm) WEIGHT
H
LBS. (kg) HANDLES INSTALLATION ORIENTATION
24 24-AGM 6
LENGTH WIDTH HEIGHT
F
54 (24) Plastic Strap
Horizontal
and Vertical
10.77 (274) 6.84 (174) 8.62 (219)
DATA SHEET
12 VOLT
MODEL 24-AGM
VOLTAGE 12
CAPACITY 76Ah @ 20Hr
MATERIAL Polypropylene
BATTERY VRLA AGM / Non-Spillable / Maintenance-Free
COLOR Maroon
WATERING No Watering Required
CHARGING TEMPERATURE COMPENSATION
ADD SUBTRACT
0.005 volt per cell for every 1°C below 25°C
0.0028 volt per cell for every 1°F below 77°F
0.005 volt per cell for every 1°C above 25°C
0.0028 volt per cell for every 1°F above 77°F
OPERATIONAL DATA
OPERATING TEMPERATURE SELF DISCHARGE
-4°F to 122°F (-20°C to +50°C). At
temperatures below 32°F (0°C) maintain
a state of charge greater than 60%.
Less than 3% per month depending on
storage temperature conditions
STATE OF CHARGE MEASURE OF OPEN-CIRCUIT VOLTAGE
PERCENTAGE CHARGE CELL 12 VOLT
100 2.14 12.84
75 2.09 12.54
50 2.04 12.24
25 1.99 11.94
0 1.94 11.64
MOTIVE 24-AGM
CHARGING INSTRUCTIONS
CHARGER VOLTAGE SETTINGS (AT 77°F/25°C)
SYSTEM VOLTAGE 12V 24V 36V 48V
Maximum Charge Current (A) 20% of C
20
Absorption Voltage (2.40 V/cell) 14.40 28.80 43.20 57.6 0
Float Voltage (2.25 V/cell) 13.50 27.00 40.50 54.00
Do not install or charge batteries in a sealed or non-ventilated compartment. Constant under
or overcharging will damage the battery and shorten its life as with any battery.
ELECTRICAL SPECIFICATIONS
VOLTAGE CAPACITY
A
MINUTES CRANKING PERFORMANCE CAPACITY
B
AMP-HOURS (Ah) ENERGY (kWh) INTERNAL RESISTANCE (mΩ) SHORT CIRCUIT CURRENT (amps)
12
@ 25 Amps C.C.A.
D
@0°F C.A.
E
@32°F 5-Hr 10-Hr 20-Hr 100-Hr 100-Hr
– –
137 500 600 67 70 76 84 1.01