Specifications
RECYCLE RESPONSIBLY
12V
Flooded
RECYCLE RESPONSIBLY
2V
Flooded
PHYSICAL SPECIFICATIONS
MODEL NAME TERMINAL TYPE
D
DIMENSIONS
B
INCHES (mm) WEIGHT
E
LBS. (kg) HYDROLINK OR SPWK HANDLES
SPRE 02 1255* 5
LENGTH WIDTH HEIGHT
C
119 (54) SPWK Braided Rope
11.66 (296) 6.94 (176) 17.55 (4 46)
DATA SHEET
2 VOLT
STATE OF CHARGE MEASURE OF OPEN-CIRCUIT VOLTAGE
PERCENTAGE CHARGE SPECIFIC GRAVITY 2 VOLT
100 1.277 2.12
90 1.258 2.10
80 1.238 2.08
70 1.217 2.06
60 1.195 2.04
50 1.172 2.02
40 1.148 1.99
30 1.124 1.97
20 1.098 1.94
10 1.073 1.92
*Polyon
™
Case
MODEL SPRE 02 1255
VOLTAGE 2
CAPACITY 1255Ah @ 100Hr
MATERIAL Polypropylene
BATTERY Deep-Cycle Flooded/Advanced Lead Acid Battery
COLOR Maroon
WATERING Single-Point Watering Kit (Optional)
PRODUCT
HIGHLIGHTS
Smart Carbon™ for Improved Performance
8 Years Battery Life Based on IEC 61427
ELECTRICAL SPECIFICATIONS
VOLTAGE CAPACITY
A
AMP-HOURS (Ah) ENERGY (kWh)
2
10-Hr 20-Hr 48-Hr 72-Hr 100-Hr 100-Hr
1039 1130 1203 1232 1255 2.51
CHARGING TEMPERATURE COMPENSATION
ADD SUBTRACT
0.005 volt per cell for every 1°C below 25°C
0.0028 volt per cell for every 1°F below 77°F
0.005 volt per cell for every 1°C above 25°C
0.0028 volt per cell for every 1°F above 77°F
OPERATIONAL DATA
OPERATING TEMPERATURE SELF DISCHARGE
-4°F to 113°F (-20°C to +45°C). At
temperatures below 32°F (0°C) maintain a
state of charge greater than 60%.
5 – 15% per month depending on storage
temperature conditions.
SOLAR SPRE 02 1255
CHARGING INSTRUCTIONS
CHARGER VOLTAGE SETTINGS (AT 77°F/25°C)
SYSTEM VOLTAGE 6V 12V 24V 48V
Maximum Charge Current (% of C
20
Rate)* 13%
Maximum Absorption Phase Time (hours) 4
Absorption Voltage ** 7.35 14.70 29.40 58.80
Float Voltage 6.75 13.50 27.00 54.00
Equalization Voltage 8.10 16.20 32.40 64.80
Do not install or charge batteries in a sealed or non-ventilated compartment. Constant under or
overcharging will damage the battery and shorten its life as with any battery.
*If charging time is limited contact Trojan Technical Support for assistance.
**In cases where controller has a bulk voltage setting, use absorption voltage setting above.