You can download the current version of the operating manual and the EU declaration of conformity via the following link: Table of contents Notes regarding the operating manual................................. 1 Safety ..................................................................................... 1 Information about the device................................................ 3 AirgoClean 10 E Transport and storage...........................................................
• • • • • • • • • • • Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged! The electrical connection must correspond to the specifications in chapter Technical data. Insert the mains plug into a properly secured mains socket. Observe the technical data when selecting extensions to the power cable. Completely unroll the extension cable. Avoid electrical overload.
Device depiction Information about the device Device description The device AirgoClean 10 E serves to filter the room air with the aim of reducing slight and medium contaminations and odours in order to improve the air quality. It is equipped with a powerful fan sucking in the air at the front. The air flows through the filter and is cleaned. Afterwards the fan releases the clean air back into the room.
Transport and storage Notice If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter. Transport A Before transporting the device, proceed as follows: • Switch off the device. • Hold onto the mains plug while pulling the power cable out of the mains socket.
Available accessories Operation Notice Avoid open doors and windows. After being switched on, the device operates fully automatically. Operating elements Warning Only use accessories and additional equipment specified in the operating manual. Using insertion tools or accessories other than those specified in the operating manual may cause a risk of injury. Designation Article number HEPA filter, filter class H11 7.160.000.
Notice Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on. Your device still does not operate correctly after these checks? Please contact the customer service. If necessary, bring the device to an authorized specialist electrical company or to Trotec for repair. Visual inspection of the inside of the device for dirt 1. 2. 3. 4. Remove the air filter. Use a torch to illuminate the openings of the device. Check the inside of the device for dirt.
1. Open the device cover (2) by rotating it counter-clockwise. Note the mark (6) on the right-hand side of the device cover. You have to rotate the device cover (2) from the closed (7) to the open position (8). 3. Pull the strip (9) to take the used HEPA filter (10) out of the device. 2 9 8 7 10 6 2. Remove the device cover (2) from the device. 4. Dispose of the used HEPA filter according to the national regulations. 5. Take the new HEPA filter out of the plastic cover.
6. Insert the new HEPA filter into the device. Make sure that the strip (9) is positioned on the outside. Technical annex Technical data Parameter Value Model AirgoClean 10 E Article number 1.580.001.010 Suitable room size 20 m2 / 50 m3 Air flow rate with HEPA filter Fan stage I 55 m3/h Fan stage II 105 m3/h Fan stage III 135 m3/h 9 7. Put the device cover (2) back on the device. Make sure that the mark (6) on the device cover and the mark (8) on the right-hand side of the device are aligned.
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.