B1E EN TRT-BA-B1E-TC-002-EN OPERATING MANUAL HUMIDIFIER
You can download the current version of the operating manual and the EU declaration of conformity via the following link: Table of contents Notes regarding the operating manual................................. 1 Safety ..................................................................................... 1 B1E Information about the device................................................ 3 Transport and storage........................................................... 4 Assembly and installation...........
• • • • • • • • Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so. Switch the device off and disconnect the power cable from the mains socket when the device is not in use. Do not under any circumstances use the device if you detect damages on the mains plug or power cable.
No. Designation Information about the device 1 Top with water tank Description of the device 2 Bottom section The device functions as a humidifier and aroma diffuser. The ultrasound technology ensures a pleasant room climate and air quality improvement. The device is equipped with an integrated scented oil tank and diffuser for optional room air aromatization. The capacity of the water tank allows for a runtime of up to 15 hours.
Transport and storage Assembly and installation Notice If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Transport Before transporting the device, observe the following: • Switch the device off. • Hold onto the mains plug while pulling the power cable out of the mains socket. • Check whether the upper part is correctly positioned on the lower part. • Lift the device at the lower part.
1. Remove the top section with the water tank (1). Please note that there may still be residual water left in the bottom section if the device was used beforehand. 5. Insert the SecoSan® Stick (optional accessory) into the water tank. 6. Screw the lid (11) firmly back onto the water tank (1). 6 1 7. Place the top correctly onto the bottom section. ð Please note that after inserting the water tank, the water immediately starts to run into the bottom of the device. 2. Turn the water tank over. 3.
Scent option Additionally, the device offers the possibility to distribute a scent during operation. Notice Never put scented oil directly into the scented oil tank, the water tank or on the membrane. Direct contact with scented oil might cause damage to plastic components or other device parts. Use standard scented oil. Proceed as follows to use the scent option: ü The device is switched off and the power cable is disconnected from the mains. 1. Remove the scented oil tank (5) from the device.
Shutdown Operation • Avoid open doors and windows. Operating elements • • 9a 9b • • • • • Warning of electrical voltage Do not touch the mains plug with wet or damp hands. Switch the device off by pressing the on/off switch (9a) for approx. 2 s. Hold onto the mains plug while pulling the power cable out of the mains socket. Empty the water tank. Empty the lower part. Use a cloth to wipe all parts of the device dry. Clean the device according to the Maintenance chapter.
Errors and faults The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list. The device does not start: • Check the power connection. • Check the power cable and mains plug for damages. • Check the on-site fusing. • Check whether the water tank indicator light is illuminated. The water tank might be empty and need refilling. • Wait for 10 minutes before restarting the device.
Cleaning the water tank The water tank should be cleaned once a week. Use a conventional descaling agent (e.g. household vinegar) for cleaning. 1. Remove the top section with the water tank (1). Please note that there may still be residual water left in the bottom section if the device was used beforehand. 1 8. Allow the water tank to dry. 9. Clean the inside of the bottom section and the mist nozzle with a conventional descaling agent (e.g.
Cleaning the nebulizer membrane Depending on the hardness of the drinking water used, deposits may form on the nebulizer membrane over time. These could affect the nebulizer performance. Therefore, the nebulizer membrane should be cleaned on a regular basis. To do so, please proceed as follows: 1. Remove the water tank (1) as described in Cleaning the water tank. 2. Remove any residual water from the inside of the device. 3. Wet the nebulizer membrane (12) with a conventional descaling agent (e.g.
1. Remove the air filter from the device. Cleaning the scented oil tank The scented oil tank should be cleaned on a regular basis. 1. Remove the scented oil tank (5) from the device. 5 2. Rinse the scented oil tank and the sponge with clear water. If required, you can use a mild cleaning agent for the scented oil tank. 3. Use a cloth to wipe the scented oil tank dry. 4. Allow the sponge to dry. 5. Push the scented oil tank (5) with the sponge back into the device. 2. Rinse the filter with warm water. 3.
Technical annex Disposal Technical data Parameter Value Model B1E Nebulizer performance 200 ml/h Runtime 15 h Power consumption 24 W Mains connection 220 V – 240 V / 50 Hz – 60 Hz Nominal current consumption 0.1 A Plug type CEE 7/16 Cable length 1.5 m Sound pressure level (1 m distance) 38 dB (A) Water tank capacity 3l Weight 1.
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.