B6E EN TRT-BA-B6E-TC-002-EN OPERATING MANUAL HUMIDIFIER
You can download the current version of the operating manual and the EU declaration of conformity via the following link: Table of contents Notes regarding the operating manual................................. 1 Safety ..................................................................................... 1 B6E Information about the device................................................ 3 Transport and storage........................................................... 4 Assembly and installation...........
• • • • • • • • Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so. Switch the device off and disconnect the power cable from the mains socket when the device is not in use. Do not under any circumstances use the device if you detect damages on the mains plug or power cable.
Information about the device Description of the device The device functions as a humidifier, aroma diffuser and air cleaner. The ultrasound technology ensures a pleasant room climate and air quality improvement. The device is equipped with an integrated scented oil tank and diffuser for optional room air aromatization. The on-demand ionization function promotes the removal of harmful substances and odours from the room air. The device comes with an automatic mode and a night mode.
Transport and storage Assembly and installation Notice If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Transport Before transporting the device, observe the following: • Switch the device off. • Hold onto the mains plug while pulling the power cable out of the mains socket. • Check whether the upper part is correctly positioned on the lower part. • Lift the device at the lower part.
Filling the water tank The water tank should be filled before first use or when the lacking water indication (16) lights up. Notice Fill the device with fresh drinking water only. The water temperature must not exceed 40 °C. Scented oil or other additives can damage the plastics and the nebulizer membrane. Info If possible, change the water on a daily basis to prevent bacterial growth. 1. Remove the mist nozzle (1) from the water tank. 2.
Scent option Additionally, the device offers the possibility to distribute a scent during operation. Notice Never put scented oil directly into the scented oil tank, the water tank or on the membrane. Direct contact with scented oil might cause damage to plastic components or other device parts. Use standard scented oil. Proceed as follows to use the scent option: ü The device is switched off and the power cable is disconnected from the mains. 1. Remove the scented oil tank (9) from the device.
Operating elements Operation • Avoid open doors and windows. 23 24 25 26 Display 14 15 16 17 22 28 18 21 20 No.
Controlling humidification The desired room humidity can be set to 40 %, 50 %, 60 %, 70 %, 80 % or OL (continuous humidification regardless of the room humidity). The desired room humidity can only be set in manual humidification mode. 1. Press the Humidity button (24) until the desired room humidity is displayed. ð The desired room humidity flashes on the segment display (14) for approx. 5 s. ð Then, the current relative room humidity is shown on the segment display (14) again.
Setting the timer For the device to switch off automatically after a predefined number of hours (up to max. 12 h) you can programme the timer. The timer can be programmed in increments of 1 hour (1 to 12 h) in manual humidification mode and automatic mode. Please proceed as follows to programme automatic switch-off: 1. Press the Timer button (25). ð The number of hours flashes on the segment display (15). 2. Press the Timer button (25) until the desired number of hours is displayed. 3.
Water is leaking: • Check whether the device is set up in a stable and upright position. • Check the water level in the lower part of the device. The water level might be too high and water is discharged via the overflow. • Check the valve in the water tank lid. The valve must be able to move freely. If necessary, clean the water tank. • Check the float in the lower part of the device. The float should be able to move freely. It may block and cause water to be discharged via the overflow.
13. If required, screw the filter cartridge with water softener (6) onto the lid (13). 14. Screw the tank lid (13) firmly back onto the water tank (2). 3. Turn the water tank over. 4. Unscrew the fuel tank cap (13). 13 13 6 6 5. Drain the residual water from the water tank. 6. Take the SecoSan® Stick out of the water tank. 7. Thoroughly rinse the water tank with a conventional descaling agent (e.g. household vinegar). 8. Thoroughly rinse the water tank and the SecoSan® Stick with clear water. 9.
Cleaning the nebulizer membrane Regenerating the water softener Depending on the hardness of the drinking water used, deposits may form on the nebulizer membrane over time. These could affect the nebulizer performance. Therefore, the nebulizer membrane should be cleaned on a regular basis. To do so, please proceed as follows: 1. Remove the water tank (2) and the mist nozzle (1) as described in Cleaning the water tank. 2. Remove any residual water from the inside of the device. 3.
10. Screw the lid (13) firmly back onto the water tank (2). 5. Push the scented oil tank (9) with the sponge back into the device. 6 Cleaning the air filter 11. Refit the water tank (2) and the mist nozzle (1) as described in Cleaning the water tank. Cleaning the scented oil tank The scented oil tank should be cleaned on a regular basis. 1. Remove the scented oil tank (9) from the device. Notice Ensure that the air filter is not worn or damaged.
4. Reinsert the air filter into the device. Disposal The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.