Operation Manual

EN 8
Operating manual – humidifier B 6 E
Controlling humidification
The desired room humidity can be set to 40%, 50%, 60 %,
70 %, 80 % or OL (continuous humidification regardless of the
room humidity).
The desired room humidity can only be set in manual
humidification mode.
1. Press the Humidity button(24) until the desired room
humidity is displayed.
ð The desired room humidity flashes on the segment
display(14) for approx.5s.
ð Then, the current relative room humidity is shown on
the segment display(14) again.
ð The desired relative room humidity is set.
Setting the nebulizer intensity
The nebulizer intensity can be set in all operating modes. The
default setting is level3.
The nebulizer intensity can be set to 6levels, with level1
corresponding to the lowest and level6 to the highest nebulizer
intensity.
1. Press the arrow buttons(27, 28) to set the desired
nebulizer intensity.
ð The current nebulizer intensity is shown on the
nebulizer intensity indication(19).
ð The desired nebulizer intensity is set.
Setting the operating mode
You can switch between the following operating modes:
Manual humidification (standard indication, 16)
Automatic mode (intelligent indication, 21)
Night mode (sleep indication, 22)
1. To select the desired operating mode, press the Mode
button(23).
ð The corresponding indication appears on the display.
Manual humidification
The device always starts in this operating mode. The current
room humidity and nebulizer intensity are shown on the display.
The desired relative room humidity can be adjusted at any time
in this operating mode. The setting options are 40%, 50%,
60 %, 70 %, 80 % or OL (continuous humidification regardless
of the room humidity).
The nebulizer intensity can be adjusted at any time in this
operating mode.
If the current relative room humidity is lower than the
desired relative room humidity, the device humidifies the
air with the selected nebulizer intensity.
If the current relative room humidity is equal to or higher
than the desired relative room humidity, the device
humidifies the air at nebulizer intensity level 1.
If OL is selected, the device humidifies the air with the
selected nebulizer intensity regardless of the current
relative room humidity.
Automatic mode
The device humidifies the air constantly and regardless of the
relative room humidity.
The desired relative room humidity cannot be adjusted in this
operating mode.
The nebulizer intensity can be adjusted at any time in this
operating mode.
In automatic mode, the device operates with the following
settings:
If the current relative room humidity is equal to or higher
than 60%, the device humidifies the air at nebulizer
intensity level 1.
If the current relative room humidity is between 40% and
60%, the device humidifies the air with the nebulizer
intensity set.
Night mode
The device humidifies the air constantly and regardless of the
relative room humidity.
In night mode, the timer is automatically set to 8h.
The desired relative room humidity cannot be adjusted in this
operating mode.
The nebulizer intensity can be adjusted at any time in this
operating mode.
The display switches off after approx. 1min and only switches
back on when a button is pressed.
In night mode, the device operates with the following settings:
If the current relative room humidity is equal to or higher
than 60%, the device humidifies the air at nebulizer
intensity level 1.
If the current relative room humidity is between 40% and
60%, the device humidifies the air with the nebulizer
intensity set.