BD11 EN TRT-BA-BD11-TC220823TTRT05-004-EN OPERATING MANUAL LASER DISTANCE MEASURING DEVICE
You can download the current version of the operating manual and the EU declaration of conformity via the following link: Table of contents Notes regarding the operating manual................................. 2 Safety ..................................................................................... 2 Information about the device................................................ 4 BD11 Transport and storage........................................................... 6 Operation .........................
Intended use Only use the laser distance measuring device BD11 for measuring distances, areas and volumes by means of the integrated laser and within the measuring range specified in the technical data. Observe and comply with the technical data. To use the device for its intended use, only use accessories and spare parts which have been approved by Trotec. Foreseeable misuse Do not use the device in potentially explosive atmospheres, or for measurements in liquids. Never point it at people or animals.
Operating elements Information about the device Device description The laser distance measuring device BD11 is used to determine distances, areas and volumes in interior spaces. Indirect measurements are carried out employing the Pythagoras function. The multi-line, illuminated display indicates the determined values. Owing to the dust- and splash-proof housing (IP54), the device is also suited for use on construction sites.
Display Technical data 11 12 13 14 15 01/10 24 16 17 23 Parameter Value Model: BD11 Weight: 23.8 g Dimensions (H x W x D): 74.5 x 33.9 x 14.7 mm Measuring range: 0.05 to 30 m / 0.17 to 98 ft Accuracy: ± 3 mm* Measuring range resolution: 1 mm 22 21 20 18 Number of recordings logged in the history: 10 19 Type of protection: IP54 Operating temperature: 0 °C to 40 °C Storage temperature: -20 °C to 70 °C No.
Transport and storage Operation Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Transport The supplied Li-ion batteries are subjects to the requirements of dangerous goods legislation. Observe the following when transporting or shipping Li-ion batteries: • The user may transport the batteries by road without any additional requirements. • If transport is carried out by third parties (e.g.
Changing the units 1. Press the Unit button (10) for a long time to switch between the units for the measured values. Available units are ft, in and m. Calling up a measured value in the device history The device automatically saves the last 10 measured values. The saved measured values can be called up as follows: 1. Briefly press the Function button (10) five times to call up the history. ð The History indication (14) appears on the display. 2.
4. Briefly press the Switch-on / measurement button (7) again to carry out the third measurement (e.g. height). ð The measured value is additionally displayed in the upper measurement value display (17). ð Upon pressing the Switch-on / measurement button (7) for the third time the device independently calculates the volume and displays this value in the lower measurement value display (20). Performing a non-stop / min and max measurement Use the non-stop measuring function to correlate measurements e.g.
Twofold indirect height measurement This method is suitable for e.g. height measurements. Maintenance and repair Charging the battery The battery should be charged when the battery is low. The battery power is shown on the display (6) in the battery status indication (16). Proceed as follows: 1. Open the rubber side cover. 2. Connect the mini USB cable to the device. C B A 1. Briefly press the Function button (10) four times. ð Line C is marked in red. 2.
Errors and faults Disposal The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list. Always dispose of packing materials in an environmentally friendly manner and in accordance with the applicable local disposal regulations. Icon Cause Remedy The battery is almost empty. Recharge the battery. Calculation error Repeat the measurement.
Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.