Operation Manual

EN Operating manual – Condenser dryer DH 30/60 AX 9
Positioning the condensation drain hose
Note:
The condensation drain hose is already installed when the device
is delivered.
1. Ensure that the condensation drain hose is properly connect-
ed to the device and is free of damage.
2. Depending on use, position the end of the condensation drain
hose as follows:
Position a sufficiently large container (at least 20 litres) be-
side the device and insert the hose end. Check the fill level
of the container regularly.
Position the end of the condensation drain hose above a wa-
ter drain. For larger distances, a longer hose of the same
type can also be used.
3. Ensure that the condensation drain hose always descends.
Switch device on
1. Ensure that the condensation drain hose has been laid and
connected properly. Do not create tripping hazards.
2. Ensure that the condensation drain hose is not bent or
jammed and that there are no objects on the condensation
drain hose.
3. Ensure that the condensation can run off properly.
4. Only have an electrically skilled person connect the power ca-
ble!
Room humidity adjustment
Set the desired humidity level via the control dial (4) of the hygro-
stat.
Automatic defrost
If the room temperature is below 15 °C, the evaporator becomes
covered in frost during dehumidification. The device then carries
out an automatic defrost. The duration of the defrost can vary.
Shut down procedure
1. Only have an electrically skilled person disconnect the power
cable!
2. Remove the condensation drain hose and any residual fluid
from it.
3. Clean the device, and especially the air filter, according to
chapter Maintenance.
4. Store the device according to chapter Storage.
12x1 mm