Operation Manual

14 EN
local air conditioner PAC 2100 X / PAC 2600 X
Switching the LEDs on the control panel on or off
The control panel illumination at the devices can be switched on
and off.
This setting can only be made using the remote control.
1. Press the LED button(23).
ð The LEDs on the control panel will be switched off.
ð The device continues to run with the selected settings.
2. Press the LED button(23) again.
ð The LEDs on the control panel will be switched back on.
Saving preferred settings
You can save your preferred settings and return to the previous
setting.
This setting can only be made using the remote control.
1. Press and hold the SHORT CUT button(20) for 3s.
ð The display(19) goes blank for 1s.
ð The current settings including operating mode, target
temperature, fan stage and night mode (if activated) will
be saved.
2. Press the SHORT CUT button(20) for 1s.
ð The display(19) goes blank for 1s.
ð The device returns to the previous setting including
operating mode, target temperature, fan stage and night
mode (if activated).
3. In order to delete the settings, press the SHORT CUT
button(20) again for 3s.
ð The display(19) goes blank for 1s.
ð The settings are now deleted.
FollowMe function
Using the FollowMe function, the remote control measures the
temperature at your current location. The degree of cooling is
controlled by the air conditioner based on the measured
temperature.
The FollowMe function can be activated in cooling mode and
during automatic operation.
1. Press the FOLLOWME button(37).
ð The FOLLOWME indication(38) appears on the
display(19).
ð The remote control sends a temperature signal to the air
conditioner every 3minutes.
2. Press the FOLLOWME button(37) again to disable the
FollowMe function.
Memory function
After a power failure during operation the device will
automatically be switched back on. The chosen operating mode
settings will be saved, a possibly programmed timer will not.
All the chosen settings (incl. timer) remain saved on the remote
control. As soon as the device receives an input from the remote
control, the settings will be transmitted from the remote control
to the device.
The compressor may start up with a delay of 3min, as it is
provided with an internal protection against direct restart.
Energy saving
Upon reaching the preselected target temperature the
compressor will be switched off automatically in order to reduce
the power consumption.
Once the preselected target temperature is exceeded, the
compressor switches back on.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator.
The device will then carry out an automatic defrost.
The compressor switches off and the fan keeps running until
defrosting is completed. The duration of the defrost process can
vary.
Do not switch the device off during automatic defrost. Do not
remove the mains plug from the mains socket.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Empty the condensation tray if necessary.
If necessary, remove the condensation drain hose and any
residual fluid from it.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Observe the operating temperature according to the
Technical data chapter.
The condensation tank may be full. Empty the
condensation tank, if need be. The error codeP1 must not
be indicated on the segment display.
Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.