Operation Manual

18 EN
local air conditioner PAC 2100 X / PAC 2600 X
4. Reinsert the air filter into the device.
Condensate discharge (manual draining)
In cooling and dehumidification mode condensate is formed,
which is mostly discharged via the exhaust air.
The remaining condensate is collected in a container within the
housing. The condensate ought to be drained regularly.
If too much condensate accumulates, the device switches off
and indicates this via an acoustic signal and the P1 indication
on the segment display(15).
1. Carefully transport or wheel the device to a suitable
location for discharging the condensate (e.g. a drain) or
position a suitable collection container under the
condensate outlet.
2. Remove sealing cap and rubber stopper from the
condensate outlet.
3. Drain the condensate.
4. Reinsert the rubber stopper in the condensate outlet and
reattach the sealing cap. Ensure the tight fit of the rubber
stopper, for otherwise there might be uncontrolled water
leakage.
ð The P1 error code on the segment display(15) will
disappear as soon as the condensate has been drained.