Operation Manual

EN Operating Manual – Construction dryer TTK 400 B - 3
Technical data
Power consumption
The device's power consumption depends on the current room
temperature and relative humidity.
Multiply the operating hours (see operating hours counter (3)) by a
consumption value of one kilowatt per hour to determine the
approximate power consumption.
To determine the precise power consumption, a separate energy
cost gauge can be set between the construction dryer and the
power source. Contact TROTEC
®
customer service if you want this
alternative version.
Parameters Values
Model TTK 400
Dehumidifying capacity, max. 75 l / 24 h
Dehumidifying capacity (20 °C / 60 % relative humidity) 30 l / 24 h
Suitable for room dimensions up to:
construction drying or clearing water damages
maintaining dryness
400 m³
800 m³
Operating temperature 0-40 °C
Working range for relative humidity 35-100 %
Volume of airflow, max. 420 m³/h
Electric connection 230 V / 50 Hz / 6.2 A
Power consumption, max. 1.4 kW
Power consumption, average 1 kW
Fuse (home) 10 A
Compressor Rotary
Refrigerant R407c
Amount of refrigerant 0.45 kg
Weight 42 kg
Dimensions (HxDxW) 854 x 480 x 510 mm
Minimum distance from walls of other objects A: Above: 50 cm
B: Behind: 50 cm
C: Side: 50 cm
D: Front: 50 cm
Sound pressure level LpA (3 m; complies with DIN 45635-01-KL3) 56 dB(A)