Operation Manual

11 EN
Operating manual – dehumidifier TTK 24 E / TTK 24 E BS / TTK 24 E DS / TTK 24 WS
3. Clean the filter using a slightly damp, soft, lint-free cloth. If
the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.
4. Allow the filter to dry completely. Do not insert a wet filter
into the device!
5. Reinsert the air filter into the device.
TANK FULL
DEFROST
OPERATION
ON
OFF
6. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank. In doing so, make sure
that the float is positioned correctly.
In doing so, make sure that the condensation tank is
inserted correctly, for otherwise the device cannot be
switched back on.
Emptying the condensation tank
If the condensation tank is full or not installed correctly, the
TANK FULL LED(10) will be illuminated. The compressor and
fan will switch off.
1. Take the condensation tank out of the device.
TANK FULL
DEFROST
OPERATION
ON
OFF
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly
using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank.
In doing so, make sure that the float is positioned
correctly.
In doing so, make sure that the condensation tank is
inserted correctly, for otherwise the device cannot be
switched back on.
TANK FULL
DEFROST
OPERATION
ON
OFF