SDS

Lead Acid Battery Wet, Filled With Acid
923330 Version #: 03 Revision date: 19-March-2018 Issue date: 19-September-2017
SDS Canada
4 / 8
Canada. Ontario OELs.
(Control
of Exposure to
Biological
or Chemical
Agents)
Components
Type Value
Form
Lead and lead compounds
(inorganic) (CAS
7439-92-1)
TWA 0.05 mg/m3
Canada. Quebec OELs.
(Ministry
of Labor -
Regulation respecting occupational
health and
safety)
Components Type Value
Antimony (CAS 7440-36-0)
Electrolyte (Sulfuric acid)
(CAS 7664-93-9)
Lead and lead compounds
(inorganic) (CAS
7439-92-1)
Biological
limit
values
ACGIH
Biological
Exposure
Indices
TWA 0.5 mg/m3
STEL 3 mg/m3
TWA 1 mg/m3
TWA 0.05 mg/m3
Components
Value
Determinant
Specimen Sampling
Time
Lead and lead compounds 200 µg/l Lead Blood
*
(inorganic) (CAS
7439-92-1)
* - For sampling details, please see the source document.
Appropriate engineering
controls
Provide adequate ventilation. Provide easy access to water supply and eye wash facilities.
Individual protection
measures, such as
personal protective equipment
Eye/face
protection
Skin
protection
Hand
protection
Other
Respiratory
protection
Thermal
hazards
General
hygiene
considerations
None under normal conditions. Leak from a damaged or opened battery: Wear safety glasses with
side shields (or goggles).
None under normal conditions. Leak from a damaged or opened battery: Wear appropriate
chemical resistant gloves.
None under normal conditions. Leak from a damaged or opened battery: Wear suitable protective
clothing. Use of an impervious apron is recommended.
None under normal conditions.
When material is heated, wear gloves to protect against thermal burns.
Always observe good personal hygiene measures, such as washing after handling the material
and before eating, drinking, and/or smoking. Routinely wash work clothing and protective
equipment to remove contaminants.
9.
Physical
and
chemical properties
Appearance
Physical state
Form
Colour
Odour
Solid.
Sulfuric acid, liquid. Lead, solid.
Not available.
Odourless.
Odour
threshold
Not available.
pH
< 1
Melting
point/freezing
point
Not available.
Initial
boiling
point and
boiling
range
112.78 - 115.56 °C (235 - 240 °F) (Sulfuric acid)
Flash point
Below room temperature (as hydrogen gas).
Evaporation
rate
< 1 (n-BuAc=1)
Flammability
(solid,
gas)
Upper/lower flammability
or
explosive
limits
Flammability
limit -
lower
(%)
4 % (Hydrogen)