Instructions / Assembly

4. Open both end links of the chain. Attach the chain to the canopy loop. Hang the fixture on the chain. Adjust fixture to desired height.
Remove excess chain. Close the links.
5. Unscrew the ring from the screwcollar loop. Let the ring and canopy slide down the chain to the top of the fixture.
Thread the lead wires and ground wire (first) through the ring and then the canopy. Thread the wires up through alternating links of the chain.
6. When the ceiling is reached, measure 6" beyond the chain and cut off the excess wire.
Separate the leads and strip of approx. 1/2" of insulation from each lead. Twist the strands of wire together.
Push the leads and ground wire up through the screwcollar loop and nipple and into the outlet box.
7. Fasten the ground wire to the green or bare copper wire
in the outlet box or to the green screw on the crossbar.
WARNING
Never fasten the ground wire to the black or "hot" wire!
Failure to follow this instruction could result in
serious injury or death
8. Fasten the white fixture lead to the white wire in the outlet box.
Fasten the wires together with an approved fastener (wire nut). Starting
about 1' below the fastener, tightly wrap the connection with electrical
tape so that the connection seals the end of the fastener.
WARNING
Make sure that there is no exposed wire or strands that
could cause a dangerous short circuit !
9. Connect the black fixture lead to the black wire in the outlet box. Fasten the joined wires as in step 8.
10. Thread the SAFETY CABLE down through alternating links of chain.
11. Slide the canopy and ring up the chain to the outlet box. Secure the canopy in place against the ceiling.
12. Thread a crimp-on cable clamp onto the SAFETY CABLE. Loop the SAFETY CABLE through the fixture loop.
13. Thread the SAFETY CABLE back through the crimp-on cable clamp. Pull cable snug and tightly crimp cable clamp in place.
DO NOT
OVER TIGHTEN THE CABLE AND CAUSE THE CHAIN TO SAG! Remove excess cable approx 1/ 2" beyond the clamp.
14.Install the lighting fixture and the loop to the ring.
15. Install 2 half circle tube, with screw locking in both ends arrows point to the position
16. Install the crystals and sleeves. And Turn the iron ring to the Angle 45with the finial Lock the ring.
17. Install the lamps (light bulbs). NOTE: This fixture is rated for Max 60 watt type B lamps.
WARNING
DO NOT EXCEED RECOMMENDED WATTAGE!
18. Restore power to circuit at breaker or fuse box.
electrical tape
approved fastener
(
wire nut
)
Nipple
Chain
Cano
py
Mounting bar
Green screw
Screw collar loop