Instructions / Assembly

1
4/22/2013
F3578 INSTALLATION INSTRUCTIONS
WARNING
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
CAUTION
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH
ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES.
INSTALLATION AND MAINTENANCE OF THIS UNIT REQUIRES AN ELECTRICIAN OR
CERTIFIED FACTORY TRAINED TECHNICIAN.
If an existing fixture is being replaced, remove it and note to which of the wires in the outlet box the fixture was attached.
DO NOT SEPARATE ANY OTHER WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING.
In regular circumstances the BLACK wire will be the "Hot" lead and the WHITE wire will be the "Neutral" or "Common" lead.
A GREEN or BARE COPPER wire is the "Ground". In older buildings it is always good practice to reconfirm the polarity of the wiring.
NOTICE
The important safeguards and instructions outlined on this sheet cannot cover all possible conditions and situations that may occur.
It must be understood that common sense, caution and care are factors that cannot be built into any product.
Caution and care must be supplied by the person(s) installing, operating and caring for this lighting fixture.
This fixture is designed to be mounted on a correctly installed standard round or octagon box or a through wiring box
with a plaster frame. The box must be securely mounted to the structure of the building.
The crossbar and hardware supplied should be used. Directly mounting the fixture to the outlet box may make it impossible to correctly align
the fixture.
FIXTURE PREPARATION
1. Remove the fixture, parts and parts bag(s) from the carton.
NOTICE:
Before discarding the carton, double check to make certain that all parts are found.
FIXTURE INSTALLATION
1. Thread the 2 mounting screws into the mounting ring. (The green screw is in the front). Attach the mounting ring to the outlet box.
Then thread the nipple into the crossbar and the hex nut onto the nipple.
2. Remove the threaded ring from the screw collar loop. Fully thread the screw collar loop onto the nipple. Place the canopy over the
Screw collar loop and against the ceiling.
Adjust the nipple so that 1/4" of threads on the screw collar loop extend beyond the canopy.
Then remove the canopy and
tighten the hex nut against the crossbar.
3. Open end links of chain and attach the chain to the screw collar loop .Close the top link of chain.
Hang the fixture on the chain at the
desired height. Remove excess chain.
Close the bottom link of chain on fixture loop ring.
4. Unscrew the ring from the screw collar loop. Let the ring and canopy slide down the chain to the top of the fixture
Thread the lead wires and ground wire (first) through chain, ring and then the canopy.
5. When the ceiling is reached, measure 6" beyond the chain and cut off the excess wire. Separate the leads and strip of approx. 1/2"
of insulation from each lead. Twist the strands of wire together. Push the leads and ground wire up through the screw collar loop and nipple and into the outlet
box.
6. Fasten the ground wire to the green or bare copper wire
in the outlet box or to the green screw on the crossbar
WARNING
Never fasten the ground wire to the black or "hot" wire!
Failure to follow this instruction could result in
serious injury or deat