Installation Sheet

FIXTURE INSTALLATION
1. Loosen the SET SCREWS (13) to remove the FRAME (11) from the FIXTURE ASSEMBLY (10) .
2. Attach the MOUNTING PLATE (1) onto the junction box using the MOUNTING SCREWS (2). This fixture is
designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted
to the structure of the building.
3. Open the end link on the CHAIN (8) and attach to the loop on the FIXTURE ASSEMBLY (10). Hang the
FIXTURE ASSEMBLY (10) on the CHAIN (8) at your desired height, and remove excess CHAIN (8).
4. Feed the wire through the CHAIN (8) , SCREW COLLAR (9), CANOPY (7), SCREW COLLAR LOOP (6),
NIPPLE (5), and MOUNTING PLATE (1), and screw the NIPPLE (5) onto the MOUNTING PLATE (1).
5. Open the top link on the CHAIN (8), and Hang the FIXTURE ASSEMBLY (10) to the SCREW COLLAR LOOP
(6).
6. Cut off excess wire, and strip the insulation off the end of the leads.
7. Attach the Ground wire (Green) to the ground inside the junction box (Generally green or bar copper wire) or
the GROUND SCREW (3) on the MOUNTING PLATE (1). NEVER CONNECT GROUND WIRE TO "HOT"
WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
8. Connect the fixture lead the ridge(s) to the neutral (Generally white) wire in the outlet box. Fasten the wires
together with an approved fastener (WIRE NUT) (4). Starting 1" below the fastener, tightly wrap the connection
with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO
EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
9. Connect the smooth fixture leads with to the hot (Generally black) wire in the junction box. Fasten the joined
wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS
COULD RESULT IN SERIOUS INJURY OR DEATH!
10. Screw the BULBS (13) (not included)up into the SOCKET of the fixture.THIS FIXTURE IS RATED FOR 60
WATT LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
11. Attach the FRAME (11) to the FIXTURE ASSEMBLY (10) and secure with the SET SCREWS (13).
12. Restore power to the outlet at the breaker or fuse box.
SOREN
F8911
INSTALLATION INSTRUCTIONS
WARNING/CAUTION
· DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS
COMPLETELY BEFORE STARTING INSTALLATION.
· TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND
MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED
FACTORY TRAINED TECHNICIAN.
· CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS
AFTER USE.
· REMOVE THE FIXTURE, PARTS AND PARTS BAG(S) FROM THE CARTON. BEFORE DISCARDING THE
CARTON, DOUBLE CHECK TO MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR
TO INSTALLATION FOR ANY DAMAGE TO THE FIXTURE.
· DIMMING: THE FIXTURE CAN BE CONTROLLED BY A WALL DIMMING DEVICE. ONLY USE
TRIAC/ELECTRONIC DIMMER. MAKE SURE THE CARTON IS MARKED FOR USE WITH LED COMPACT
FLUORESCENT-INCANDESCENT LIGHT SOURCE ONLY. THESE CAN BE PROVIDED BY YOUR LOCAL
ELECTRICAL DISTRIBUTOR, HOME CENTER, OR HARDWARE STORE.
· PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS
www.hvlgroup.com
Questions? We're here to help!
Contact us at CustomerService@hvlgroup.com
ITEM DESCRIPTION
PART NUMBER
1
MOUNTING PLATE
HDW-F8911
2
MOUNTING SCREWS
HDW-F8911
3
GROUND SCREW
HDW-F8911
4
WIRE NUTS
HDW-F8911
5
1/4 NIPPLE
HDW-F8911
6
SCREW COLLAR LOOP
HDW-F8911
7
CANOPY CPY-F8911
8
CHAIN CHN-F8911
9
SCREW COLLAR
HDW-F8911
10
FIXTURE ASSEMBLY FAS-F8911
11
FRAME
FAS-F8911
12
BULBS NOT INCLUDED
13
SET SCREWS
HDW-F8911
14
GLASS GLS-F8911
1
2
3
4
5
6
7
8
9
10
11
12
13
14