Datasheet

Distributed by Conrad Electronic SE • Klaus-Conrad-Str. 1 • D-92240 Hirschau
Datasheet
Item no. TC-S18-05N-1, 2, TC-S18-05P-1, 2
V1_09062017_01_en
1
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior
written approval by the editor. Reprinting, also in part, is prohibited. This publication represents the technical status at the time of printing.
© Copyright 2017 by Conrad Electronic SE.
Specifications
Item Standard
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Power supply voltage 12 24 VDC. Ripple (p-p) : 10% max.
(operating voltage range) (10 30 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type See product selection
Control load current output (See note 1.) 200 mA max. (32 Vdc max.)
Residual voltage 1 V max. (under load current of 200 mA with cable length of 2 m)
Operation mode See product selection
(with sensing object approaching)
Protection circuit Output reverse polarity protection, power source circuit reverse
polarity protection,
Surge suppressor, Short-circuit protection
Ambient air temperature Operating: -40°C to 70°C, Storage: -40°C to 80°C( with no icing or condensation)
Temperature influence (See note 1.) ±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C
Ambient humidity Operating : 35% to 95%, Storage : 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 1,000 m/s2, 10 times each in x, Y and Z directions
Note 1. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between
30 and 32 VDC, use a load current of 100 mA max.,

Summary of content (3 pages)