Installation and connection
It is important that you read these operating instructions, including the safety instruc-
tions thoroughly and carefully before rst use to ensure that you will launch the relay
board properly! If in doubt, let a specialist do the installation and connection.
Only connect boards when they are disconnected from voltage/current. Otherwise,
there is a risk of a life-threatening electric shock!
a) Installation
The relay board must be installed so that accidental contact is avoided. Here also a sufcient
distance to low voltage or non-mains-carrying circuit parts must be observed. Secure the board
so that it will not come loose.
Warning! There is a risk of a life-threatening electric shock if the work is done incor-
rectly!
b) Connection
Two-pole connection terminal “IN”: Control voltage (230 V/AC, 50 Hz) connection for switch-
ing the relay contacts (connection phase/L and neutral conductor/N is not important)
When control voltage is applied, a control LED will go on next to the connection
terminals. You can route the LED light. to the front of an enclosure using suitable
light conductors, for example.
Two three-pole connection terminals “CO/ NC/NO”: Relay switching contacts; two potential-
free switching contacts
CO = Common switching contact
NC = Switch output “normally closed” (closed when idle)
NO = Switch output “normally open” (open when idle)
Secure all cables carrying mains voltage appropriately. Ensure appropriate strain
relief of the mains cables dependent on the place where the relay board is installed.
Maintenance
The relay board is maintenance-free. However, check the connection leads for damage from
time to time and that the connections are mechanically secured.
Only an authorised expert may perform repairs.
Before you start working on the module, disconnect the mains cable from voltage/
current; the same also applies to all devices connected to the relay contacts.
Disposal
Electronic devices are recyclable material and do not belong in the household
waste. Dispose of an unserviceable product in accordance with the relevant statu-
tory regulations.
Technical data
Control/operating voltage .................... 230 V/AC, 50 Hz
Switching capacity (resistive load) ....... max. 150 W, max. 1250 VA
Switching current ................................. max. 5 A
Switching voltage ................................. max. 125 V/DC, max. 250 V/AC
Switch contacts ................................... relay, 2x changeover contacts, potential-free
Dimensions .......................................... 72 x 20 x 36.5 mm (L x W x H)