Data Sheet

a. Disconnect temperature changes in the initial value should be within + 5 ° c,
b.Contact resistance should be belowin100m Ω
continue experiment in 10000times after action
5 Other items:
5.1 Disconnect the temperature detection 5.1 heating rate should be controlled for 1 ° c / 1min, Use process
cannot bear strong impact and stress.
5.2 Models of specifications
02 —— production specifications
XXX —— voted disconnect temperature
6 This standard should separ a tely conclude when not related to other matters or customer requirements.
opening and reset temperature drawing
NO. Disconnect
temp.
Reset temp. NO. Disconnect
temp.
Reset temp.
30 30
±
3 20 95 95
±
5 70
±
15
35 35
±
3.5 25 100 100
±
5 70
±
15
40 40
±
4 30 105 105
±
5 75
±
15
45 45
±
4.5 33 110 110
±
5 75
±
15
50 50
±
5 35 115 115
±
5 80
±
15
55 55
±
5 42
±
6 120 120
±
5 85
±
15
60 60
±
5 45
±
8 125 125
±
5 85
±
15
65 65
±
5 48
±
10 130 130
±
5 90
±
15
70 70
±
5 50
±
12 135 135
±
5 95
±
15
75 75
±
5 53
±
14 140 140
±
5 100
±
15
80 80
±
5 55
±
15 145 145
±
5 100
±
15
85 85
±
5 60
±
15 150 150
±
5 105
±
15
90 90
±
5 65
±
15 155 155
±
5 110
±
15
Distributed by Conrad Electronic SE, 92240 Hirschau, Germany