Data Sheet
a. Disconnect temperature changes in the initial value should be within + 5 ° c,
b.Contact resistance should be belowin100m Ω
continue experiment in 10000times after action 。
5 Other items:
5.1 Disconnect the temperature detection 5.1 heating rate should be controlled for 1 ° c / 1min, Use process
cannot bear strong impact and stress.
5.2 Models of specifications
02 —— production specifications
XXX ℃ —— voted disconnect temperature
6 This standard should separ a tely conclude when not related to other matters or customer requirements.
opening and reset temperature drawing
NO. Disconnect
temp.
Reset temp. NO. Disconnect
temp.
Reset temp.
30 30
±
3 ℃ ≥ 20 ℃ 95 95
±
5 ℃ 70
±
15 ℃
35 35
±
3.5 ℃ ≥ 25 ℃ 100 100
±
5 ℃ 70
±
15 ℃
40 40
±
4 ℃ ≥ 30 ℃ 105 105
±
5 ℃ 75
±
15 ℃
45 45
±
4.5 ℃ ≥ 33 ℃ 110 110
±
5 ℃ 75
±
15 ℃
50 50
±
5 ℃ ≥ 35 ℃ 115 115
±
5 ℃ 80
±
15 ℃
55 55
±
5 ℃ 42
±
6 ℃ 120 120
±
5 ℃ 85
±
15 ℃
60 60
±
5 ℃ 45
±
8 ℃ 125 125
±
5 ℃ 85
±
15 ℃
65 65
±
5 ℃ 48
±
10 ℃ 130 130
±
5 ℃ 90
±
15 ℃
70 70
±
5 ℃ 50
±
12 ℃ 135 135
±
5 ℃ 95
±
15 ℃
75 75
±
5 ℃ 53
±
14 ℃ 140 140
±
5 ℃ 100
±
15 ℃
80 80
±
5 ℃ 55
±
15 ℃ 145 145
±
5 ℃ 100
±
15 ℃
85 85
±
5 ℃ 60
±
15 ℃ 150 150
±
5 ℃ 105
±
15 ℃
90 90
±
5 ℃ 65
±
15 ℃ 155 155
±
5 ℃ 110
±
15 ℃