Manual

4
Operating Instructions
USB CAN bus Analyzer
Item no: 2806230
1 Intended use
The product is a CAN bus analyzer. Use the product to read, send and monitor data in Con-
troller Area Networks (CAN bus) via the supplied analyzer computer software.
The product is intended for indoor use only. Do not use it outdoors.
Contact with moisture must be avoided under all circumstances.
If you use the product for purposes other than those described, the product may be dam-
aged.
Improper use can result in short circuits, fires, or other hazards.
The product complies with the statutory national and European requirements.
For safety and approval purposes, you must not rebuild and/or modify the product.
Read the operating instructions carefully and store them in a safe place. Make this product
available to third parties only together with the operating instructions.
All company names and product names are trademarks of their respective owners. All rights
reserved.
2 Delivery contents
Converter
USB cable
Analyzer software (available from www.conrad.com/downloads)
Operating instructions
3 Latest product information
Download the latest product information at www.conrad.com/downloads or scan the QR
code shown. Follow the instructions on the website.
4 Description of symbols
The following symbols are on the product/appliance or are used in the text:
The symbol warns of hazards that can lead to personal injury.
5 Safety instructions
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information on
proper handling, we assume no liability for any resulting personal injury or
damage to property. Such cases will invalidate the warranty/guarantee.
5.1 General
The product is not a toy. Keep it out of the reach of children and pets.
Do not leave packaging material lying around carelessly. This may become dangerous
playing material for children.
If you have questions which remain unanswered by this information product, contact our
technical support service or other technical personnel.
Maintenance, modifications and repairs must only be completed by a technician or an
authorised repair centre.
5.2 Handling
Handle the product carefully. Jolts, impacts or a fall even from a low height can damage
the product.
5.3 Operating environment
Do not place the product under any mechanical stress.
Protect the appliance from extreme temperatures, strong jolts, flammable gases, steam
and solvents.
Protect the product from high humidity and moisture.
Protect the product from direct sunlight.
5.4 Operation
Consult an expert when in doubt about the operation, safety or connection of the
product.
If it is no longer possible to operate the product safely, take it out of operation and pro-
tect it from any accidental use. DO NOT attempt to repair the product yourself. Safe op-
eration can no longer be guaranteed if the product:
is visibly damaged,
is no longer working properly,
has been stored for extended periods in poor ambient conditions or
has been subjected to any serious transport-related stresses.
5.5 Connected devices
Also observe the safety and operating instructions of any other devices which are con-
nected to the product.
6 Product overview
6.1 Components
1
2
3
4
5
6
7
8
9
10
11
12
Component Description/Function
1
Input port DC-IN
Connect an auxiliary 8 - 28 V/DC power supply (if
needed).
2
USB port USB
USB data and power supply port (5 V/DC, max.
0.5 A)
3
Indicator light WORK/PWR
Indicator light CAN2/CAN1
Indicator lights
4
Dip switch RES2
120 Ω resistance switch of the CAN2 channel
5
Dip switch RES1
120 Ω resistance switch of the CAN1 channel
6
CAN port CAN2_H
CAN2 high signal line
7
CAN port CAN2_G
CAN2 ground
8
CAN port CAN2_L
CAN2 low signal line
9
CAN port CAN1_H
CAN1 high signal line
10
CAN port CAN1_G
CAN1 ground
11
CAN port CAN1_L
CAN1 low signal line
12
Reset button Reload
Press and hold for approx. 6s to restore default
settings.
6.2 Indicator lights
Indicator light Colour Intensity/Pattern Status description
PWR
Red Bright Power supply is normal
Dim Power supply failure
WORK
Blue Always bright Device initialization passed; on
standby
Dim Device initialization failed
Flickering There is a software calling device
on the PC side
CAN1, CAN2
Green Dim CAN channel no data transmission
Flashing green Corresponding CAN channel has
data transmission
Solid green Corresponding to CAN channel
bus error