8 Machinery control buttons Control machinery according to receiver wiring.
Dual function buttons (2 speeds) (No. 2832827 / 2832829)
Single function buttons (1 speed) (No. 2832830 / 2832831)
9 Emergency stop button The emergency stop button controls the operational state of the remote control
buttons. It has two states: engaged and disengaged.
Push to engage. Disables all remote control buttons.
Rotate to disengage. Activates the button START.
8.2 Transmitter indicator lights
Status indications of indicator light STATUS on transmitter:
Colour Pattern Indication
Green Solid Indicates normal operation.
Conditions:
Button START is pushed.
Machinery control button is pushed.
Green Flashing Indicates faulty operation.
Condition:
No transmitter button is pushed.
Fault:
Receiver has no power.
Red Solid Indicates normal operation.
Condition: with the emergency stop button engaged:
Button START is pushed.
Machinery control button is pushed.
Condition: with the emergency stop button disengaged:
Machinery control button is pushed but button START has not been
pushed yet.
Red Flashing Indicates faulty operation.
Condition:
Machinery control button is pushed.
Fault:
Transmitter has no power (example: batteries are depleted).