*) Specialist knowledge required for the installation:
In particular, the following expertise is required for installation:
the applicable “5 safety rules”: Switch off power; secure against switching back
on; determine voltage-free status; earthing and short-circuiting; cover or fence off
nearby live parts
C
hoose appropriate tools, meters and, if necessary, personal protective equipment
Evaluation of the measurement results
Selection of the electrical installation material to ensure the shutdown conditions
IP protection types
Installation of the electrical installation material
Type of mains supply network (TN system, IT system, TT system) and the con-
nection conditions that follow from them (classical earthing, protective earthing,
required additional measures, etc.)
If you do not have the expertise required for the installation, do not install it
yourself, but entrust the work to a qualied electrician.
a) General information
The unauthorised conversion and/or modication of the product is not allowed for
safety and approval reasons.
Maintenance, adjustment or repair work may only be carried out by an expert/author-
ised service centre familiar with the hazards involved and the relevant regulations.
The product is not a toy and should be kept out of the reach of children! There
is danger of a life-threatening electric shock! Install the product out of the reach
of children.
Protect the product from extreme temperatures, direct sunlight, strong vibrations,
high humidity, moisture, combustible gases, vapours and solvents.
Handle the product with care; it can be damaged by impacts, blows or falls even
from a low height.
Do not leave the packaging material lying around carelessly as it may be a danger
to children.
On industrial sites, the accident prevention regulations of the association of the
industrial workers‘ society for electrical equipment and utilities must be followed!
Consult a qualied technician, if you are not sure how to operate or how to safely
connect the equipment.
Maintenance, adjustment and repair work should only be carried out by an expert
or a specialist workshop.
If you have any questions that are not answered in these operating instructions,
please contact our technical customer service or other technicians.
b) Connection
Item no. 1661882 and 1661883:
The construction of the product corresponds to protection class II (double or rein-
forced insulation). However, an internal connector for the protective earth conduc-
tor is provided. The product may thus be used for with protection class II and with
protection class I luminaires. A mains cable with protective earth conductor must
be used for luminaires of protection class I. The protective earth conductor of the
mains cable must be connected to the protective earth conductor of the connected
luminaire. Failure to observe this poses a danger to life from electric shock!
Item no. 1661884 and 1661887:
The construction of the dimmer corresponds to protection class II (double or rein-
forced insulation). Only a luminaire of protection class II can be connected to the
dimmer. Do not connect luminaires to this dimmer that require a protective earth
conductor! There is a risk of a life-threatening electric shock!
Item no. 1661885 and 1661886:
The construction of the dimmer corresponds to protection class II (double or rein-
forced insulation). Only luminaires with an operating voltage of 12 V/AC may be
connected to the dimmer.
Make the connection only after ensuring the absence of any voltage/ current.
Ensure that the insulation of the housing is neither damaged nor destroyed.
The mains socket to which the product is connected must be easily accessible.
Never overload the product. Note the maximum load capacity in the chapter “Tech-
nical data”.
Observe the minimum load capacity in the chapter “Technical data”. Malfunction-
ing may occur if the minimum load capacity is not reached.
c) Operation
The product is not a toy. Devices operated on mains voltage should not be used by
children. Therefore, be especially careful when children are around.
Use the product where it is out of the reach of children.
Do not use the product in rooms with adverse environmental conditions, where
combustible gases, vapours or dust are or may be present! There is a danger of
explosion!
Connecting to the mains voltage and operating the product is only permissible if
the housing is closed.
Never use the product in a vehicle.
Install all cables in such a way that nobody may trip over them.
Operating instructions
Dimmer
Item no. 1661882 (slide dimmer, white, 60 - 300 W)
Item no. 1661883 (slide dimmer, black, 60 - 300 W)
Item no. 1661884 (slide dimmer, white, 35 - 60 W)
Item no. 1661885 (rotary knop dimmers, black, 25 - 150 W)
Item no. 1661886 (rotary knop dimmers, white, 25 - 150 W)
Item no. 1661887 (slide dimmer, black, 35 - 60 W)
Intended use
The dimmer is a retrotting for luminaires already in service with incandescent or halogen
lamps without ballast. This enables you to adjust the brightness of the luminaire innitely. The
dimmer is only suitable for connecting to the mains voltage (see chapter “Technical data”).
For safety and compliance reasons, the product must not be converted or modied in any way.
If you use the product for other purposes than those described above, the product may be dam-
aged. Moreover, improper use involves risks such as short-circuits, re, electric shocks, etc.
Please read the operating instructions carefully and do not discard them. Please include these
operating instructions when you pass the product on to a third party.
This product complies with the applicable national and European Regulations. All names of
companies and products are the trademarks of the respective owners. All rights reserved.
Package contents
Dimmer
Operating instructions
Up-to-date operating instructions
Download the latest operating instructions via the link www.conrad.com/downloads or scan the
QR code. Follow the instructions on the website.
Explanation of symbols
The lightning symbol inside a triangle is used when there is a potential risk of per-
sonal injury, such as electric shock.
An exclamation mark in a triangle indicates important steps in these operating in-
structions which should be absolutely observed.
The arrow symbol indicates specic tips and advice on operation.
The product is designed according to protection Class II (reinforced or double insu-
lation, protective insulation).
The product is only intended to be installed and used in dry indoor spaces; it must
not get damp or wet.
Observe the operating instructions.
Safety instructions
Please read the operating instructions carefully and pay particular attention
to the safety instructions. We do not assume liability for any injuries/mate-
rial damages resulting from failure to observe the safety instructions and the
information in these operating instructions regarding the proper use of the
product. Furthermore, in such cases, the warranty/guarantee will be null and
void.
Attention, important note!
Only persons with relevant electro-technical knowledge and experience
should carry out the installation! *)
If it is not installed properly, you risk:
your own life
the life of the person using the electrical system.
If it is not installed properly, you risk severe damage to property, e.g., by re.
There is a risk of you being held liable for personal injury and material damage.