TRUE INDUCTION TRIPLE BURNER INDUCTION COOKTOP MANUAL TI-3B 1 TRIPLE BURNER INDUCTION COOKTOP MANUAL
TABLE OF CONTENTS Control Panel Overview Cooktop Installation Important safety Information Product Specifications How to Use > Power Invariance Technology > Using the Temperature Setting > Using the Timer Function > Built-In Safety Shut Off > Turning Off Unit VI. Compatible Cookware VII. Cleaning & Maintenance VIII. Troubleshooting Error Codes I. II. III. IV. V. 1 2-4 5-6 6 7 7-8 8 8 9 9 9 10 10-11 Thank you for purchasing the True Induction Triple Burner Induction cooktop.
I. Control Panel Overview 1. Upper Left Cooking Zone 2. Lower Left Cooking Zone 3. Right Cooking Zone 4. Ceramic– Glass 5. Upper Left Touch Control Panel 6. Right Touch Control Panel 7. Lower Left Touch Control Panel 8. Power Option Display 9. Lower Power Key 10. Raise Power Key 11. Cooking Zone ON/OFF Key 12. Time Control Key 13. Power Button 1 3 4 2 5 6 7 8 11 9 12 13 10 3 TRIPLE BURNER INDUCTION COOKTOP MANUAL P.
II. Cooktop Installation Dimensions and Placement for Cut-out in Countertop This appliance is not user serviceable. Installation must be completed by a qualified technician. WARNING! FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of the unit. To eliminate the risk of burns or fire due to overheating, cabinets located above the induction cooktop should be avoided or allowed a minimum of 30’’ clearance.
II. Cooktop Installation Continued... First feed the power wire through the hole and to the location of the power receptacle underneath the cabinet. The 'h'' overhang on the induction cooker comes with pre-installed foam gasket. Peel off the adhesive protector on the bottom of the gasket and set the induction cooker into the cutout. Gently press down on the induction cook top to secure the adhesive gasket to the countertop. The cook top should be sitting on the supports previously installed.
II. Cooktop Installation Continued... Clearance Needed for Air Circulation Below you will see a diagram of the air flow. Be sure not to block either the intake or exhaust For proper air circulation, allow at least 3" of clearance from the bottom of the induction cooker to any shelving or storage. The underside of the countertop should not be closed off from the cabinetry underneath for better air flow. 6 TRIPLE BURNER INDUCTION COOKTOP MANUAL P.
III. Important Safety Information When using electrical appliances, basic safety precautions should always be followed. For the True Induction cooker, even with built-in safety features, it is essential to heed all precautions: When the unit is on, do not touch outside the control panel as the surface may contain residual heat. To protect against electric shock, do not immerse cord plugs or cooker in water (or other liquid substances).
III. Important Safety Information Continued... This appliance has a polarize plug (one blade is wider than the other). To reduce the risk of electric shock, the plug will fit on the outlet only one way. If the prongs do not fit fully, reverse the plug. If it still does not fit, contact the seller for warranty support; do not attempt to modify the plug in anyway. To properly turn off unit press the Power button.
V. How to Use There are 2 plugs for this unit. The UPPER and LOWER LEFT ZONES are controlled by the left plug (total power is 1800W). And the RIGHT ZONE is controlled by the right plug (power is 1500W). WARNING! The left and right plug must utilize two separate dedicated 15 amp breakers. The Power button will light up and the unit will sound to indicate on. The device will remain in standby mode, awaiting user direction.
V. How to Use Continued... Power Invariance Technology Continued... NOTICE FOR UPPER AND LOWER LEFT ZONES ONLY: 1. If only one zone is being used and the other zone is off, the zone being used can be utilized to max level 10. 2. If the UPPER and LOWER LEFT ZONES are both being used in HEAT mode at the same time, the max setting of one zone is level 7 and the max settings of two zones combined will reach level 10.
V. How to Use Continued... Built-In Safety Shut Off The True Induction cooktop is designed to automatically shut off after 150 minutes of use. This built-in auto shut off is a safety feature. This function occurs for both the HEAT and TEMP settings. The panel displays EE code and sounds indicating this auto-off setting.
VII. Cleaning & Maintenance Please follow these directions along with important safety steps for cleaning advised at the beginning of the manual: Before cleaning always switch OFF the device and wait for it to be completely cool. Clean the unit after each use to remove food residues. Wipe off the glass-ceramic plate and the plastic surface with a slightly damp cloth (mico-fiber works best). Dishwashing soap may be used when necessary. Make sure that no water seeps into the device.
VII. Troubleshooting Error Codes Continued... If the display shows an error code, please reference this sheet for a potential solution: Error Code Cause and Potential Solution E1 Voltage is under 75V E2 Voltage is over 145V E3 IGBT in short circuit, contact the seller for support. E4 Temperature sensor is defective. It may be caused by a concave pot. Change pot and restart the induction process. If the problem persists then contact the seller for support.