Owner's manual

P-SOLO Ribbon OPERATION MANUAL
12
TROUBLESHOOTING
Symptom
No signal output. Main power switch
is on, but no LED’s are illuminated.
Solution
Check AC power source and cord.
Check fuses (open fuse drawer, remove fuse
holder, inspect fuses)
No signal output. Main power switch
is on and some LED’s are
illuminated.
Check continuity of mic and electric
instrument cables.
Check continuity of output cables.
Output signal is distorted. Outputs
are connected for balanced
operation.
Make sure gain is adjusted so that the OL
indicator does not activate during the audio
program.
Make sure the high output capability of this
unit is not overloading the device or
monitoring system to which it is connected -
Check continuity of output cable.
Make sure outputs are not connected to a
load impedance of less than 600 ohms.
Output signal is distorted. Outputs
are connected for unbalanced
operation.
Make sure the minus (-) output signal pins are
connected to the shield and not left
unconnected. See “Output Cable Connection”
section.
Check troubleshooting tips for balanced
operation (above).
Hum can be heard in the audio
program.
Check continuity of output cables (particularly
shields).
Disconnect shields on one end of output
cables. (Not appropriate for unbalanced
connections.)
Electric instrument connected to the
Instrument input does not produce a
signal or signal is distorted.
Check continuity of electric instrument cables.
Check the batteries or AC power source of
any “foot pedal effects processors connected
to the Instrument input.
Make sure that the instrument cables have
standard tip-sleeve 1/4” phone plugs. - DO
NOT use TRS plugs.