Instruction Manual

P2
analog
OPERATION MANUAL
17
when used with Channel 1 as a
stereo pair
OFF for individual channel mode and ON for
Mid-Side mode.
 Make sure the 180selectors for both
Channels 1 and 2 are OFF.
In M-S mode the stereo channels
are reversed (Channel 1 is Right
and Channel 2 is Left)
 Make sure the front of the bi-directional “Side”
mic is aimed 90 degrees to the left of the axis
of the Mid mic. Alternatively, select 180 on
Channel 2 to reverse channel positions.
In M-S mode the stereo channel
phasing is incorrect
 Make sure the 180selectors for both
Channels 1 and 2 are in the same position.
Electric instrument connected to a
Direct Input does not produce a
signal or signal is distorted.
 Check continuity of electric instrument cables.
 Check the batteries or AC power source of
anyfoot pedal” effects processors connected
to the Direct Input.
 Make sure that the instrument cables have
standard tip-sleeve 1/4” phone plugs. - DO
NOT use TRS plugs.
Radio Frequency Interference can
be heard in the audio program
(swishing sound or audio from a
radio transmitter).
 Make sure that mic cables are of good quality
and that the shield is properly connected.
Avoid excessive length.
 Make sure that earth ground connection is
maintained via the AC power cord - DO NOT
use an isolator.
 Make sure the unit is located away from
known sources of radio frequency energy.
.
REGISTRATION and WARRANTY
Don’t forget to register your P2
analog
by filling out the enclosed Registration Card and
returning it to us. This allows TRUE Systems to contact you regarding any updates,
upgrades or applications information that may become available.
SUNRISE ENGINEERING and DESIGN INC. (SUNRISE) warrants the TRUE
systems P2
analog
to be free from defects in material and manufacture, when
properly installed and used according to instructions in the Operation Manual, for a
period of one year from the date of sale to the original purchaser. Units returned for
warranty repair to SUNRISE or an authorized TRUE Systems repair facility will be
repaired or replaced at the manufacturers option, free of charge. Supplementary
shipping charges will apply to units returned to addresses outside the continental USA.
All units returned to SUNRISE or authorized TRUE systems repair facility must be
prepaid, insured and properly packaged. Purchaser must obtain a Return Material