Manual

PRECISION 8i
OPERATION MANUAL
15
 Drum kits: use an M-S pair for drum overhead micing.
 Vocal and instrumental ensembles: use M-S to give realistic perspective to backup
vocals or instrumental groups.
 Individual instruments or vocals: try M-S on acoustic guitar and in situations where
you wish to capture room ambience.
 Broadcast/film sound: use M-S to capture audience noise or background ambience.
M-S can also be used in TV and film work to match the sonic image width to the
visual image width.
Optional Level Indicator Modes
The Peak-Hold level indicators can operate in two modes. As supplied, only the OL and
PK indicators will hold (after they are activated) until RESET is depressed. An optional
mode is available which causes the -3 and -6 indicators to also hold until RESET is
depressed. This mode can be helpful in live sound and recording applications where the
PRECISION 8i is remotely located from the device(s) to which it is connected. Jumpers
inside the unit select this optional mode. If you wish to configure the unit for this mode,
proceed as follows:
WARNING - ELECTRIC SHOCK HAZARD. Dangerous voltage exists inside
the enclosure of this product. This operation should only be performed by
qualified personnel. NEVER open the product enclosure while the AC power
cord is attached.
 Disconnect AC power cord.
 Remove the twelve screws securing the top cover to the enclosure. Remove the
cover.
 Locate the eight upright printed circuit boards along the front panel.
 Select level indicator mode by setting jumpers (J2) as shown below.
J2 J2
Normal Mode Optional Mode
(OL, PK remain on) (OL, PK, -3, -6 remain on)
 Replace cover and secure with twelve screws. Make sure no tools, loose hardware,
debris, etc. remain in the unit prior to attaching the cover.