Spec Series Manual

16
WHY:
THE DEFROST TIME IS THE TIME OF DAY DEFROST CYCLES ARE INITIATED.
Time of Day must be set ensure that factory set defrost times are
occur at the correct times. By adding a cycle you will be adding an
extra specifi c defrost start time.
HOW:
A. To see the defrost times press and hold the info button and
the stand-by button at the same time.. “ScL” will appear.
See image 1.
B. Push the “up” button until “dh1” appears. See image 2.
C. Press and hold the info button to see the “defrost time”.
See image 3.
Note: Clock times are displayed in 24 hour format ranging from
0-23.5.
D. Release and push the info button to scroll “dh1” - “dh6” which
show the factory pre-set defrost times. See image 4. Additional
time of day may be added when the time for defrost shows “---”.
E. While pressing and holding the info button press the up or
down button to change “defrost time”. See image 5.
F. Once the defrost time” has been added release the info
button. Wait 30 seconds for the display to show temperature. See
image 6.
the stand-by button at the same time.. ScLwill appear.
HOW TO CHANGE A “DEFROST CYCLE”
Push the upbutton until dh1appears. See image 2.
A. To see the defrost times press and hold the info button and
Press and hold the info button to see the defrost time.
Release and push the info button to scroll dh1- dh6which
While pressing and holding the info button press the up or
Once the defrost timehas been added release the info
1
3
2
4
5
6
ALL OTHER SETTINGS ARE FACTORY PRE-SET AND SHOULD NOT BE CHANGED.
If you have any questions, please call TRUE technical service.
Phone: 800-325-6152 • Email: service@truemfg.com
LAE Electronic Control
Info/Set Point
Button
Manual Defrost/
Down Button
Manual Activation/
Up Button
Stand-By
Button
Compressor
Running
Activation of 2nd
Parameter Set - NA
Alarm - NA
Cabinet in Defrost
Evaporator Fan
Running
LAE Control Icons
May need to unlock control.
This can only be changed if defrost mode parameter (DFM) is set for “RTC”.