12
LAE Electronic Control
Info/Set Point
Button
Manual Defrost/
Down Button
Manual Activation/
Up Button
Stand-By
Button
SETTING TIME OF DAY
WHY:
TO MAKE SURE THE CABINET DOES NOT INITIATE
DEFROST & GET WARM DURING TIMES OF HIGH USAGE.
Control may be designed to initiate defrost at specifi c
times of the day.
HOW:
A. To change the time of day, press and release the info
button . “t1” will appear.
Press the up button until “min appears.
See image 1.
B. While pressing and holding the info button ,
press the up or down button to change the
clock minutes. See image 2.
C. Once the minutes have been set correctly, release the
info button and “hrs will appear on the display.
See image 3.
D. While pressing and holding the info button ,
press the up or down button to change the
clock hours. See image 4.
Note: When changing the clock hour, the clock will be
displayed in 24 hour format ranging from 0-23.
E. Once the hour has been set correctly, release the info
button .
Wait 5 seconds for the display to show temperature.
See image 5.
press the up or down button to change the
Press the up button until min appears.
press the up or down button to change the
press the up or down button to change the
button . t1will appear.
While pressing and holding the info button ,
button .
While pressing and holding the info button ,
info button and hrs will appear on the display.
1
2
3
4
5
May need to unlock control. Does not adjust for daylight savings time.
This is only necessary if the defrost mode parameter (DFM) is set for “RTC”.