Instruction Manual
SPEC SERIES
TEC_TM_141 | REV. A | EN
06/30/2022 Page 15 of 24
www.truemfg.com
Cabinet Setup (cont.)
Heated Drain Pan Installation (Current Design)
STR/STA/STG1D
Required Tools
• 1/4" Hex Head Driver.
• Socket Set
• 3/4" Socket
• Drill
Before you begin
Uncrate the cabinet as described on page 5. Install castors (see
“Installing 6" Leveling Legs or Castors” page 6) and level the cabinet
(see “Leveling” page 7).
1. Locate the heated drain pan (HDP) and the associated bracket
and hardware. See figs. 1 and 2.
2. On the underside of the cabinet, locate the two drain elbows.
See fig. 3.
3. Connect the provided drain hose extensions to the drain
elbows. See fig. 4.
4. Install the HDP bracket on the underside of the cabinet.
See fig. 5.
5. Position the HDP in the HDP bracket. Then, route the drain
hose extensions through the bracket and into the HDP.
See fig. 5.
6. Connect the HDP power cord to the receptacle located behind
the outer back cover. See fig. 6.
Fig. 5. Heated drain pan bracket
positioned and hoses routed.
Fig.6.
Fig. 3. Drain elbow location underneath
the cabinet.
Fig. 4. Hoses connected to the drain
elbows.
Fig. 1. Locate the box with the heated
drain pan (HDP) and its components.