Use and Care

11
True
traditional reach-ins
www
.truemfg.com
STARTUP
A. The compressor is ready to operate. Plug in the cooler.
B. Temperature controls are factory-set to give refrigerators
an approximate temperature of 35°F (1.6°C) and freezers
an approximate temperature of -10°F (-23.3°C). Allow unit
to function several hours, completely cooling cabinet before
changing the control setting.
TemperatureControlLocationandSettings.
•Electronictemperaturecontrolislocatedonrearofunitor
behind access grill.
•LAEtemperaturecontrolislocatedonthefrontofcabinet
countertop or in/behind louvered grill.
•Mechanicaltemperaturecontrolislocatedinsideofunit.
See website for adjustments, sequence of operation, and more
information.
C. Excessive tampering with the control could lead to service
difficulties. Should it ever become necessary to replace
temperature control, be sure it is ordered from your TRUE
dealer or recommended service agent.
D. Good air flow in your TRUE unit is critical. Be careful to
load product so that it neither presses against the back wall,
nor comes within four inches of the evaporator housing.
Refrigerated air off the coil must circulate down the back wall.
NOTE: If the unit is disconnected or shut off, wait five minutes
before starting again.
RECOMMENDATION - Before loading product we recommend
you run your TRUE unit empty for two to three days. This allows
you to be sure electrical wiring and installation are correct and no
shipping damage has occurred. Remember, our factory warranty does
not cover product loss!
LIGHT SWITCH LOCATION:
LightswitchlocationdependsupontheT-Seriesmodel.MostT-Series
models will have the light switch located inside the unit on the right
side of the ceiling. Most instances the switch is located next to the
temperature control. Some models have the switch located on the
right side of the evaporator housing along the interior ceiling.
OPERATION
MECHANICAL TEMPERATURE CONTROLS
COIL SENSING
An evaporator coil sensing temperature control ensures that the evaporator coil will remain clear
of frost and ice by not allowing the compressor to restart until the coil temperature is above the
freezingtemperature.Thisisconsideredanoff cycle defrost.
AIR SENSING
Anairsensingtemperaturecontrolusedinafreezerapplicationwillrequireadefrostcyclewith
heaters to ensure that the evaporator coil is kept clear of frost and ice.