Manual

CHAPTER 4: PROGRAMMING & OPERATION
Truefitness.com / 800.426.6570 / 636.272.7100 22
ADVANCED CONSOLE FUNCTIONS:
WARNING:
Misconfiguration of the console may cause damage to the unit and void the manufacturer warranty. If
necessary, please contact TRUE Fitness Technical Support at 800-883-8783 for assistance.
Diagnostics Mode:
Diagnostics mode contains several tools and information that are useful in diagnosing technical issues.
Entering Diagnostics Mode:
a) Remove the safety key
b) Press and hold the + and Speed keys until the console beeps. (approx. 3 seconds)
c) Re-insert the safety key.
Navigating Diagnostics Mode:
Using the up and down incline keys, users can scroll through the available options and press enter to make a selection.
Options include:
Total TimeThe total number of hours the unit has been used.
Total Distance The total distance the unit has run.
Average Speed The overall average speed at which the unit has been used.
Cooldown Time Adjusts the length of the cooldown workout segment (use the + and - speed keys).
Error Log Contains a list of recent error codes to assist with troubleshooting.
Power cycle the unit to exit diagnostics mode.
Calibration Mode:
Calibration mode will conduct a basic test of the drive and incline systems to ensure that they are operating as intended.
Calibration may also be used by technicians to troubleshoot system errors.
WARNING:
This process will take full control of the treadmill and can be dangerous if caution is not taken.
Calibration can take up to two minutes to complete.
Do not stand on the treadmill during the calibration procedure.
Verify that the machine is free of all parts and tools.
Keep children and animals at a safe distance.
Calibration Steps:
a) Remove safety key
b) Press and hold INCLINE UP & INCLINE DOWN for approximately 3 seconds until a beep is heard
c) Re-insert the safety key and Press START to initiate incline calibration
d) After incline calibration has completed, press START to initiate speed calibration
e) At 0.5 MPH press START
f) At 12.0 MPH press START to stop (Calibration Successful)
g) Remove the safety key to exit