User's Manual

TEC_TM_009 REV. E03/31/2022Page 10 of 56 TRUE RESIDENTIAL
®
PRIOR TO INSTALLATION
ELECTRICAL REQUIREMENTS
TR-30/ TR-36
For all built-in models, the electrical supply should
be located within the shaded area shown in the
illustration. Follow the National Electrical Code
and local codes and ordinances when installing
the receptacle. A dedicated circuit, supplying only
this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified person in order to avoid a hazard.
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
NOTE: THE OUTLET MUST BE CHECKED BY A
QUALIFIED ELECTRICIAN TO BE SURE THAT IT
IS WIRED WITH THE CORRECT POLARITY.
VERIFY THAT THE OUTLET IS PROPERLY
GROUNDED.
ANTI-SWEAT FOAM END PANELS
When installing two units side-by-side, it is
recommended to leave a 58" gap between the
cabinets, to ensure that moisture does not develop.
Anti-sweat foam end panels can be purchased from
our parts department by calling (844) 849-6226, or
emailing trueresidentialparts@truemfg.com. If installing
anti-sweat foam end panels, we recommend that a
panel be applied to each of the units being joined
together.
TR-30/TR-36
FRONT VIEW ROUGH OPENING
& ELECTRICAL AREA
84"
(2134 mm)
PROUD
INSTALL
84
1
/
4
"
(2140 mm)
FLUSH
INSTALL
77"
(1956 mm)
2"
(51 mm)
8"
(204 mm)
Electrical located
in this area.
Proud
TR-30 – 29-¾"
(756.7 mm)
TR-36 – 35-¾"
(908 mm)
Flush
TR-30 – 30-¼"
(769 mm)
TR-36 – 36-¼"
(921 mm)