Owner's Manual
Cardio
950
CHAPTER 6: ADDITIONAL INFORMATION
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 41 of 47
Fault CN03:
Stuck Key
Console Membrane Key stuck down/closed
Membrane key is
damaged
Contact dealer or TRUE service
Fault CN04:
Lower
Board
Comm Fault
(Treadmill
Only)
Console
Brainboard fails to receive timely
communication responses from
lower board - Fault aer 3 retries
Loose Cable
Power cycle
Check cable connections
Smart Card, MCB, or
Console
Contact dealer or TRUE service
Fault CN05:
No Lower
Control
Console
No lower board connected to
console - detection wires not
connected.
Loose Cable
Power cycle
Check Cable Connection
Console Congure
Incorrectly
Re-congure console
Fault CN06:
Cong
Mismatch
Console
Console is congured for a product
dierent than that to which it is
connected.
Console Congure
incorrectly
Power cycle
Re-congure console
Loose Cable Check cable connections
Fault CN07:
Calibration
Timeout
Console
Incline Calibration was not able to
complete within allowed time.
Low AC Line Voltage
Retry calibration
Verify AC Voltage at Outlet
Fault CN08:
Calibration
Failed -
Lower
Limit Not
Reached
Console
During incline calibration, the
incline stalled before reaching what
should be the lower limit.
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable connections
Incline Potentiometer
value out of range
Run incline calibration
Contact dealer or TRUE service
Fault CN09:
Insert Safety
Key
Console Emergency Circuit opened
Safety Key not engaged Re-insert safety key
Loose Cable Check cable connections
Switch Damaged Contact dealer or TRUE service
Fault CN10:
E-Stop Fault
Console
A test of the emergency circuit has
failed
Console Catch Power cycle
Safety Key not engaged Reinsert safety key
Loose Cable Check cable connections
Switch Damaged Contact dealer or TRUE service
Fault CN24:
BB Comm
Fault
Console
SBC cannot communicate with
Brainboard
Console
Power cycle
Contact dealer or TRUE service
Fault CN25:
Firmware
Mismatch
Console
Firmware on brainboard not
compatible with SBC soware
Corrupt soware
Power cycle
Recongure Console
Firmware and soware
versions are not
compatible
Re-install soware/rmware
Contact dealer or TRUE service