Fault IN04:
Incline Max/Min
Incline
Incline value is out of
expected operating
range - may indicate that
it is disconnected.
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable connections
Run incline calibration
Incline Potentiometer
value out of range
Contact dealer or TRUE service
Fault D100:
Motor
Controller Fault
DC MCB
Motor Control Board
Fault
Motor Control Board
Power cycle
Contact dealer or
TRUE service
Fault D101:
Lower
Board
Communication
Fault
DC MCB
Endex did not receive
communication
from BB in 18
seconds
Loose cable
connection
Power cycle
Check cable
connections
Motor Control Board
Contact dealer or TRUE service
Upper display/console
Fault D103:
Motor
Controller Fault
DC MCB
Low Incoming AC
Voltage
Low AC Line Voltage
Power cycle
Check AC line voltage
Fault D104:
Motor
Controller Fault
DC MCB
Motor Control Board
Fault
Motor Control Board
Power cycle
Contact dealer or
TRUE service
Fault D106:
Motor
Controller Fault
DC MCB
High Incoming AC
Voltage
High AC line voltage Check AC line voltage
Motor Control Board
Power cycle
Contact dealer or
TRUE service
High belt/deck
friction
Lubricate treadbelt
Fault D107:
Motor
Over Current
DC MCB
High Incoming AC
Voltage
High AC line voltage Check AC line voltage
Fault D108:
Motor
Over Current
DC MCB
High Incoming AC
Voltage
High AC line voltage Check AC line voltage
Motor Control Board
Power cycle
Contact dealer or
TRUE service
High belt/deck
friction
Lubricate treadbelt