Fault D109: Motor
Controller Zero
Current
DC MCB
Low Incoming AC
Voltage
Low AC Line Voltage
Power cycle
Contact dealer or
TRUE service
Fault D110: Motor
Controller
Overcurrent
DC MCB
High Incoming AC
Voltage
High AC line voltage Check AC line voltage
Motor Control Board
Power cycle
Contact dealer or
TRUE service
High belt/deck
friction
Lubricate treadbelt
Fault D111: Motor
Controller Voltage
Overload
DC MCB
Low Incoming AC
Voltage
Low AC Line Voltage
Power cycle
Check AC line voltage
Contact dealer or
TRUE service
Fault D112: Motor
Controller
Undervoltage
DC MCB
Low Incoming AC
Voltage
Low AC Line Voltage
Power cycle
Check AC line voltage
Contact dealer or
TRUE service
Fault D113: Motor
Controller Control
Fault
DC MCB
Incline Stall - incline
not
moving when
commanded
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable
connections
Run incline calibration
Incline Potentiometer
value out of range
Contact dealer or TRUE service
Acme Nut jammed
Motor bearings
Fault D114: Lower
Board Incline Range
Fault
DC MCB
Incline out of range
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable
connections
Run incline calibration
Incline Potentiometer
value out of range
Contact dealer or
TRUE service