ELECTRICAL SPECIFICATIONS
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord. For personal
safety, this appliance must be properly grounded.
To minimize the depth of the cutout opening, the
electrical outlet must be positioned as shown below.
Outlet must be flush with wall.
Before your new unit is connected to a power supply,
check the incoming voltage with a volt meter. If
anything less than 100% of the rated voltage for
operation is noted, correct immediately.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall outlet to minimize the
possibility of electric shock hazard from this appliance.
A 115V AC, 60 Hz, 15 amp circuit breaker and
electrical supply are required.
Each unit requires a dedicated circuit. Have the wall
outlet and circuit checked by a qualified electrician to
make sure the outlet is properly grounded.
If the outlet is a standard 2-prong outlet, it is your
personal responsibility and obligation to have it
replaced with the properly grounded 3 prong wall
outlet.
Do not use an extension cord or two prong adaptor.
Electrical ground is required on this appliance.
2" 2"
8"
Rear wall of cut out
The unit should always be plugged into its own
individual electrical circuit, which has a voltage rating
that matches the rating plate. This provides the best
performance and also prevents overloading house
wiring circuits which could cause a fire hazard from
overheated wires. Never unplug your refrigerator by
pulling on the power cord. Always grip plug firmly and
pull straight out from the outlet.
Repair or replace immediately all power cords that
have become frayed or otherwise damaged. Do not use
a cord that shows cracks or abrasion damage along its
length or at either end. When moving the refrigerator
away from the wall, be careful not to roll over or
damage the power cord.
OUTDOOR USE
All True undercounter units are UL-rated for outdoor
use.
In regions that have high dewpoint/high humidity, it is
possible that you will see some condensation on the
glass and possibly around some of the gasket seals.
For best operation, it is recommended that your True
unit be stocked full with product.
To winterize your True unit, it is recommended once
the temperature reaches below 32ºF consistently that
products are removed from the unit, the unit is either
unplugged or turned OFF, and a cover is placed over
the unit.
Installation – For best operation, it is recommended
that your True unit is installed so that the countertop
of your outdoor kitchen/bar covers the door or drawer
gasket. Cutout opening should be a minimum of 24
inches deep and unit should be installed “flush.
Please note that door/drawer gaskets do not provide a
water tight seal against the elements.