Aventa comfort AU Operating instructions Installation instructions To be kept in the vehicle! Page 2 Page 10
Aventa comfort AU Symbols used Contents Symbols used ......................................................................... 2 Safety instructions .............................................................. 2 Notes on using air conditioning systems ........................ 3 Symbol indicates a possible hazard. Operating instructions Remote control ....................................................................... Start-up .........................................................................
The refrigerant circuit contains R 407C refrigerant and must only be opened in the factory. The air inlets / outlets at the external unit and the air distributor must not be obstructed under any circumstances. This is essential in order to ensure that your device operates correctly. In order to avoid damage to the compressor, no uphill or downhill slopes with an incline of more than 8 % must be driven on when the device is being operated while driving (e.g. with generator or voltage converter).
Operating instructions Remote control The symbols in the display are visible depending on the settings.
Start-up Before switching on, be sure to check that the camp site power supply fusing is sufficient (230 V). In order to prevent the power cable of the recreational vehicle from overheating (minimum cross-section 3 x 2.5 mm²) the cable drum must be fully unwound. The remote control must always be pointed at the infra-red receiver in order to perform the individual switching commands. Before switching on for the first time, the remote control must be tuned to the IR receiver.
Reset right / left front front / rear rear Resets the settings of the remote control to the factory settings when pressed using a ballpoint pen, for example. Setup symbol flashes. right / left Resend ceiling / floor The previous settings are resent. ceiling / floor rear Tune the remote control to the air conditioning system that is going to be operated. Settings set to “Circulated air”, fan level low, no timer set.
Accessories Technical data Filter set, 2 pieces (part no. 40091-16800). Fig. 5 Troubleshooting Fault Cause / Remedy Device not cooling –– Thawing procedure in progress –– Remote control temperature setting reached or too high Device not heating –– Defrosting process running (outside temperature between 4 °C and 7 °C –– Outside temperature below 4 °C Device cooling / heating inadequately or not at all –– Filter soiled, change filter.
Installation dimensions (in mm) The clearance around the air distributor must allow the air to blow out without obstructions. The side clearance must be at least 40 mm. The pivoting range of flaps and doors must be taken into consideration. 40 248 1008 67 0 4 38 00 0 3 25 - 110 52 40 46 670 0 40 78 0 35 Fig. 6 46 Fig. 9 Air inlets / outlets 523 400 (350) 660 400 (380) 195 (215) 530 Fig.
Declaration of conformity Truma warranty policy 1. Information about the manufacturer The warranty is given by Service Australia for 12 months from the date of purchase against any defect arising from faulty materials or workmanship. Name: Address: Truma Gerätetechnik GmbH & Co. KG Wernher-von-Braun-Str. 12, D-85640 Putzbrunn 2.
Installation instructions 12 V adapter for air distributor lighting 1 pc. (part no. 40091-33000) Fig. 16 Fig. 12 The unit must only be installed and repaired by an expert.
Cut-out installation 400 x 400 Installation with new cut-out For optimum sealing we recommend the use of the sealing frame that is available as accessory (part no. 40091-19000). For vehicles without an existing cut-out: required cut-out 350 x 380 mm. For installation with a sealing frame, please refer to the installation instructions provided with the sealing frame. Place template on installation location on vehicle, mark cutout (350 x 380 mm) and cut it out.
Preparation for power cable connection Securing the device Provide leadthrough for mains cable to connection point, e.g. in the false ceiling. Screw the two brackets (marked with an arrow in the direction of travel) to the device using the 4 provided M6 x 70 screws (with screw sealant). Torque 1.8 Nm If the roof is more than 50 mm thick, M6 screws (length = roof thickness + 30 mm) with tensile strength of 8.8 must be used. The screws must be secured with low-strength screw sealant (e.g. Loctite). Fig.
Securing the air distributor Inserting the filters Connect the cable from the air distributor to the electronics unit. Insert filters into panels and attach to the air distributor. Fig. 26 Fig. 24 Screw air distributor (arrow in direction of travel) to bracket with 6 screws M6 x 12 mm. The covering tape that is available as an accessory can be used to compensate for the gap between the air distributor and the roof. Fig. 27 Fig. 28 230 V electrical connection Fig.
In Australia, always notify the Service Australia if problems are encountered; in other countries the relevant service partners should be contacted (www.truma.com). 40091-00284 · 00 · 06/2018 · © Having the equipment model and the serial number ready (see type plate) will speed up processing. Leisure-Tec Australia Pty. Ltd. Service Australia 50 Metrolink Circuit, Campbellfield, VIC 3061 Australia Telephone: +61 1300 07 2018 E-Mail: service@leisure-tec.com.