Product Manual

7
Technical data
Determined on the basis of EN 14511 or Truma test conditions
Designation
Saphir comfort RC AU, comfort air conditioning system
Number of structural units
1
Dimensions L x W x H
628 x 400 x 290 mm
Weight
approx. 23.5 kg
Power supply
230 V – 240 V ~, 50 Hz
Maximum cooling power
2.4 kW
Heating power
1.7 kW
Effective power consumption
0.98 kW
Starting current
20 A (150 ms)
Power consumption
4.2 A / 35 °C
Protection class
IP X5
Energy Efficiency Rate (EER)
2.4
Volume flow (cold air)
max. 380 m³/h
Refrigerant
R 407C
Refrigerant content
see type plate on unit
Compressor oil
Diamond MA32, 300 cm³
Noise
depending on installation situation
Maximum incline of vehicle during operation
5° / 8 %
Usage limits
+4 °C to +43 °C.
An interior air sensor prevents the compressor from operat-
ing at temperatures of less than +16 °C during cooling.
An anti-freeze sensor prevents non-permitted ice formation
on the evaporator coil.
A temperature switch prevents excessive current and tem-
perature at the compressor.
Right reserved to make technical changes!
Circulated air intake
from inside
Cold air /
warm air outlet
Supply air
intake from
the outside
Supply air outlet
to the outside-
downwards
Throttle
Compressor
Fan
Fan
Filter
Function diagram
Evaporator /
condenser
Condenser /
evaporator
Fig. 10
IR remote control battery change
Only use micro-batteries that will not leak, type LR 3, AM4,
AAA, MN 2400 (1.5 V).
The battery compartment is on the rear of the remote control.
When inserting new batteries, make sure the positive / nega-
tive terminals are connected correctly!
Fig. 7
Empty, used batteries can leak and damage the remote
control! Remove the batteries if the remote control is
not being used for a long period of time.
The tuning between the remote control and the air con-
ditioning system is retained if the batteries are removed.
No warranty given for damage caused by leaking
batteries.
Disposal
Before disposing of a defective remote control, always re-
move the batteries and dispose of them correctly.
The device must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-life Vehicle Regulation) must be observed.
Accessories
Sound muffler for installation in the cold air duct for additional
noise reduction inside the living compartment.
(Part no. 40090-00038).
Fig. 8
The flexible air conditioning intake allows the air conditioning
system to be installed in a space that is sealed off from the
interior (e.g. false floor or rear storage space) and prevents
contaminated air from being drawn in.
(Part no. 40090-59100).
Fig. 9