Operation Manual

15
Fault
Cause
Rectification
After switching on
(winter and summer opera-
tion) none of the LEDs are lit.
No operating voltage.
Device fuse or vehicle fuse
defective.
Check 12 V battery voltage, charge if necessary.
Check all electrical plug connections.
Check the unit or vehicle fuse and replace if necessary
(see fuses).
The green LED comes on
when the unit is switched
on, but the heater does not
operate.
The temperature setting
on the control panel is
lower than the room
temperature.
Select higher room temperature at the control panel.
Green LED flashes after
heater is switched off.
After-running is active in
order to reduce the unit’s
temperature.
No error. Coasting operation switches off after
max. 5 minutes.
Red LED flashes 6 x. Insufficient fuel due to
insufficient fuelling, empty
tank, and / or inclined
vehicle orientation.
Fill tank with fuel. Then fill the fuel line as described under
“Initial start-up”.
Red LED flashes (except
6 times) or red LED shines.
Malfunction of the heating
device.
Please contact the Truma Service Centre.
Yellow LED flashes 1 x. Possible under-voltage
< 11.5 V.
Use the electrical power from the battery carefully,
e.g. restrict lighting.
Charge battery.
Yellow LED flashes 2 x. Under-voltage < 10.2 V. Check battery voltage, charge if necessary.
Short-term immediate measure: switch off heavy load
or start up vehicle engine until the heater starts running
(approx. 4 minutes).
Battery capacity inadequate, if necessary exchange old
battery.
Over-voltage > 16.4 V. Check the battery voltage and power supply such as e.g.
the charging device.
Yellow LED flashes 3 x.
Yellow LED flashes 4 x.
Open window above cowl
(window switch).
Warm air temperature
and / or water temperature
exceeded:
Not all warm air ducts
are connected.
Hot-air outlets blocked.
Recirculated air intake
blocked.
Summer operation with
empty water tank.
Close window.
Check whether the 4 warm air ducts are connected.
Check individual outlet apertures.
Remove blockage from recirculated air intake.
Fill boiler with water.
Yellow LED flashes 5 x. Room temperature sensor
or cable defective.
Please contact the Truma Service Centre.
Yellow LED flashes 6 x. Water temperature
exceeded in summer
mode.
Fill boiler with water.
Yellow LED flashes 7 x. Control panel or control
panel cable defective.
Please contact the Truma Service Centre.
Trouble-shooting list
Flash code on the control panel
Flash sequence LED:
On: 0,5 seconds
Off: 0,5 seconds
Pause between the flashing sequence: 3 seconds