Operation Manual
10
Trouble-shooting list
Fault Cause Rectification
Not heating up. No operating
voltage.
– Restore power
supply.
–
Taking an ex-
tremely long time
to heat up in
230 V operation
Heating element
furred.
– Descale water
system (see
maintenance).
–
If these measures do not remove the failure, please contact
the Truma Service Centre.
Technical data
determined in accordance with Truma test conditions
Water content
5 litres
Operating pressure
max. 1.2 bar (only use pump without non-return valve)
Power supply
230 V ~, 50 Hz
Power consumption
1.3 A (300 W)
Thermal cut-out
65 °C
Over-temperature protection
85 °C
Heating time from approx. 15 °C to approx. 60 °C
approx. 50 minutes
Weight (without contents)
2 kg complete with drain and venting valves
Dimensions
length 37 cm, height 23 cm, width 22 cm
Conformity Declaration
The Therme complies with the requirements of EN 60335,
EMC directive 89/336/EEC, low voltage directive 73/23/EEC
and the associated standards and technical specifications, and
is therefore entitled to bear the CE symbol.
The right to effect technical modifications is reserved!